background image

 

© Aurora Scientific, 2015                                           VER. 1.00 

page 1 

 
 

 

 

 

 

Water Cooler 

826A

 

 

Publish Date: 7/6/2015 

Manual Version 1.00 

www.AuroraScientific.com 

  

 

 

 

 

 

 

 
 

 

 

 

 

 

Содержание 826A

Страница 1: ...Aurora Scientific 2015 VER 1 00 page 1 Water Cooler 826A Publish Date 7 6 2015 Manual Version 1 00 www AuroraScientific com...

Страница 2: ...2015 VER 1 00 page 2 Copyright 2015 Aurora Scientific Aurora Scientific 25 Industry Street Aurora ON Canada L4G1X6 Tel 1 905 727 5161 Toll Free N America 1 877 878 4784 Fax 1 905 713 6882 Email techsu...

Страница 3: ...Water Cooler Instruction Manual Model 826A Aurora Scientific 2015 VER 1 00 page 3 Revision History Date Version Number Document Changes 07 06 2015 1 0 Initial Draft...

Страница 4: ...g the Liquid Reservoir 6 2 3 Positioning the Unit 7 2 4 Module Operation 8 3 Maintenance 9 4 Performance Guarantee Technical Support Warranty and Repair Information 10 4 1 Performance Guarantee 10 4 2...

Страница 5: ...e 5 1 Introduction The 826A Water Cooler is intended to be used as a simple liquid coolant circulator with Aurora Scientific 800 Series apparatus The Water Cooler incorporates a brushless DC pump to c...

Страница 6: ...e hose screws over the end of the hoses before mating the hose to the back of the circulator Once the hoses have been firmly pressed on tighten up the hose screws to secure the connection see Figure 1...

Страница 7: ...stopped Once full replace the cap and unplug the power adapter from the system until ready for use If the fluid refuses to flow through the system immediately when power is connected it is likely that...

Страница 8: ...y switching the 825A on or off Once the unit has been plugged in the fan speed can be set with the two position switch located on the back panel of the coolant circulator The low setting is in general...

Страница 9: ...t is full approximately 1 5cm or from the top and top up as necessary Aurora Scientific recommends replacing the coolant annually to keep your system operating optimally If you run out of coolant dist...

Страница 10: ...e Our performance guarantee states if for any reason a new product does not meet your research needs then you can return it to Aurora Scientific for exchange or a full refund The performance guarantee...

Страница 11: ...Scientific will be sent to the manufacturer for credit or replacement Ultimate disposition of these items will depend upon the manufacturer s decision All shortages must be reported within ten 10 day...

Страница 12: ...ntroller For muscle lever repairs we require the motor lever arm motor cable and control electronics Please don t send the power cord 3 Prepare Customs documents Canadian Clients no customs documents...

Страница 13: ...r choice or via parcel post If possible we prefer that you ship via FedEx You are responsible for both the shipping and brokerage charges so please mark the waybill accordingly Please don t ship freig...

Страница 14: ...cally commutated with brushless DC design Voltage Range 8 to 13 2 VDC Max System Pressure 22 PSI Head Pressure 390 m bar 12 VDC Maximum Flow 350 L h 1 54 US Gal min 12VDC Fan Voltage 12 VDC Current 0...

Отзывы: