Determine fastenings.
Produce drill holes with appropriate cross-section.
For the mounting dimensions refer to the hole layout
drawings „
i
nStaLLation
Stepe
3 - 5
“ or project-specific
documents and drawings).
Secure fasteners against loosening; e.g. by applying
removable thread-locking compound such as “Loctite”.
Carefully clear away drilling swarfs to prevent
seals from being damaged.
Avoid surface scratches, for example by using
masking tape.
I
nstallatIon
step
6
a
:
r
igiD
Drive
mounting
on
the
winDow
CaSement
n
ote
If necessary, use washers. These are depen-
ding on the type of screws used.
LO
C
TI
TE
Casement
bracket F41
1x Screw M3x20
Frame bracket
K94
4x Screw M5x10
(self-tapping)
4x Washers A5.3
FL
M5
RA
parallel
min. 8
42 ±2
12 - 18
12
FL
RA
parallel
parallel
1
3
site-supplied
m5
site-supplied
1
2
k 94
f 41
- main closing edge or auxillary closing edge
- inward opening windows
n
ote
Screws - for mounting on the window - are to
be provided by the customer!
Make sure it is parallel to casement edge.
„Casement bracket“ center and „chain out-
put“ must be in line.
Make sure they are parallel to casement edge.
Mount the casement bracket
F41
- with on-site
screws (
M5
) - on the frame.
Mount the frame brackets
K94
- with on-site screws
(
M5
) - on the window casement.
06
1.
)
2.
)
3.
)
4.
)
5.
)
FL
RA
reference edge
max. 4 Nm
reference
edge
4
5
3