51
KS 2
(24 V DC / 230 V AC)
Multi-drive operating:
KS 2
as master / slave
Only with factory programming or
customer programming with UniPC USB interface.
WH
:
is used for communication, (in systems with
synchronized multi-drive operation (S12 drive)
Optional: Master and Slave and with
max. 1 locking drive is possible
Multi-drive operating mit M-COM
WH
:
is used for communication, (in systems with
synchronized multi-drive operation (S12 drive)
Optional: 1 to 4 window drives and
max. 2 locking drives are possible
Individual configuration: Multi-drive operating with M-COM and locking drive
A maximum of
three individual window drives
and
one locking drive
are possible.
On-site: Second drive cable (looped through)
Configuration is done by
M-COM
.
e
leCtriC
C
onneCtion
Set
230V
/
24V
24V
24V
KS2
Master
Slave
WH
BN
BU
230 V AC
KS2
24 V DC
24 V
+
+
-
-
KS2
WH
BN
BU
BN BU
M-COM
24 V DC
KS2
24 V DC
+
+
-
-
KS2 (R)
WH
BN
BU
BN
BU
M-COM
24 V DC
24 V DC
24 V DC
FVUx
24 V DC
WH
BN
BU
WH
BN
BU
KS2 (R)
KS2 (R)
08
Junction box
site-supplied
Junction box to be site supplied
Polarity
reversal
n
ote
Individual
configuration
KS2 connecting cable:
24V DC,non-halogen
~ 3m, 3 x 0,5 mm
2
Junction box
site-supplied
Polarity
reversal
On-site: Second cable
On-site: Second cable
24 V
- voltage output
On-site: Second cable
Содержание 521620
Страница 57: ...57 KS2 24 V DC 230 V AC Notes 08...
Страница 58: ...58 KS2 24 V DC 230 V AC Notes 08...
Страница 60: ...9000000201_V5 0_KW17 21...