42
KS 2
(24 V DC / 230 V AC)
hsk
Determine fastenings.
Produce drill holes with appropriate cross-section.
For the mounting dimensions refer to the hole layout
drawings „
i
nStaLLation
Stepe
3 - 5
“ or project-specific
documents and drawings).
Secure fasteners against loosening; e.g. by applying
removable thread-locking compound such as “Loctite”.
Carefully clear away drilling swarfs to prevent
seals from being damaged.
Avoid surface scratches, for example by using
masking tape.
Make sure it is parallel to casement edge.
„Casement bracket“ center and „chain out-
put“ must be in line.
Casement
bracket F41
1x Screw M3x20
Frame bracket
K93
4x Screw M5x10
4x Washers A5,3
1
2
FL
M5
FL
parallel
min. 8
42 ±2
1
site-supplied
f 41
Make sure they are parallel to casement edge.
reference edge
I
nstallatIon
step
6
d
:
r
igiD
Drive
mounting
on
the
tranSom
- main closing edge
- outward opening windows
n
ote
n
ote
There are different mounting options for the
frame bracket
K93
.
Holes above
(strips facing outward)
Holes below
(strips facing inward)
If necessary, use washers. These are depen-
ding on the type of screws used.
a
ssembly
of
the
D
rive
06
Mount the casement bracket
F41
- with on-site
screws (
M5
) - on the window casement.
Mount the frame brackets
K93
- with on-site screws
(
M5
) - on the transom.
FL
RA
parallel
30
M5
site-supplied
k93
3