43
KS 2
(24 V DC / 230 V AC)
Note cable routing!
(see chapter „
C
abLe
routing
“)
Note softlauf modus!
(see chapter „
S
oft
run
moDe
“)
Check swiveling area! (see chapter
„
a
fety
C
heCK
anD
p
erforming
teSt
run
“).
RA
2
1
6
f 41
ks 2
Route the connection cable on the transom. Cable must
be protected against damage (shearing-off, kinking,
splitting).
Attache the
KS 2
drive
in the frame brackets
K93
.
Tighten the
KS 2
drive
with self-tappinge screws
M5
and washers
(max. 4 Nm).
Apply the control voltage of the
KS 2
drive
(e.g. using
a tester).
Move out the chain of
KS 2
drive
~ 100 bis 150 mm.
n
ote
For multi-drive operation actuate all
KS 2
drives
together
.
(see chapter:
E
lEctric
c
onnEction
)
Secure the chain of
KS 2
drive - with screw
-
in the casement bracket
F41
.
FL
RA
max. 4 Nm
M5
(SW4)
a
ssembly
of
the
D
rive
06
FL
RA
6
6
ks 2
ks 2
k93
5
4 3
k93
3
Содержание 521620
Страница 57: ...57 KS2 24 V DC 230 V AC Notes 08...
Страница 58: ...58 KS2 24 V DC 230 V AC Notes 08...
Страница 60: ...9000000201_V5 0_KW17 21...