5.3.2.3. Terminal compartment: close
Short-circuit due to pinching of cables!
Risk of electric shock and functional failures.
→
Carefully fit socket carrier to avoid pinching the cables.
1.
Insert the socket carrier [5] into the cover [1] and fasten with screws [4].
2.
Clean sealing faces of cover [1] and housing.
3.
Check whether O-ring [3] is in good condition, replace if damaged.
4.
Apply a thin film of non-acidic grease (e.g. petroleum jelly) to the O-ring and
insert it correctly.
5.
Fit cover [1] and fasten screws [2] evenly crosswise.
6.
Fasten cable glands and blanking plugs applying the specified torque to ensure
the required enclosure protection.
Once the power supply is connect, initialisation is started provided all prerequisites
are fulfilled.
➭
23
FQM 05.1 – FQM 12.1 / FQMEx 05.1 – FQMEx 12.1
Electrical connection
Содержание FQM
Страница 35: ...35...