4.
Assembly
4.1.
Mounting position
The product described in this document can be operated in any mounting position.
For horizontal mounting position, the fail safe unit requires reinforcement to relieve
the flange connection to the valve.
Figure 7: Reinforcement for horizontal mounting position (example)
The reinforcement is made at both threads provided for transport. For FQM 05.1/07.1
= M10 thread; for FQM 10.1/12.1 = M12 thread.
We recommend glueing the screws using thread sealing material to avoid contact
corrosion in the thread.
To compensate for vibration, we recommend using additional all-metal cushions as
available with Stop-Choc ®.
Support by AUMA
AUMA offers an own support. The support is fixed at the output drive flange using
suitable fastening clamps. It includes all-metal dampers to compensate for vibration.