Table 5:
Weights for actuators and actuator controls
1)
approx. [kg]
Type
Part-turn actuator
21/29
SQ 05.2/SQEx 05.2
21/29
SQ 07.2/SQEx 07.2
26/34
SQ 10.2/SQEx 10.2
35/42
SQ 12.2/SQEx 12.2
Actuator controls
7/12
AC01.2/ACExC 01.2
Indicated weights apply to actuators with 3-phase AC motors, standard output drive and standard
electrical connection. Weights for actuator controls with standard electrical connection.
1)
3.2.
Storage
Danger of corrosion due to inappropriate storage!
→
Store in a well-ventilated, dry room (maximum humidity 70 %).
→
Protect against floor dampness by storage on a shelf or on a wooden pallet.
→
Cover to protect against dust and dirt.
→
Apply suitable corrosion protection agent to uncoated surfaces.
Risk of damage due to excessively low temperatures!
→
Actuator controls may only be stored permanently down to –30 °C.
→
On request, actuators controls may be transported in specific cases and for
short duration at temperatures down to –60 °C.
Long-term storage
For long-term storage (more than 6 months), observe the following points:
1.
Prior to storage:
Protect uncoated surfaces, in particular the output drive parts and mounting
surface, with long-term corrosion protection agent.
2.
At an interval of approx. 6 months:
Check for corrosion. If first signs of corrosion show, apply new corrosion protec-
tion.
3.3.
Packaging
Our products are protected by special packaging for transport when leaving the
factory. The packaging consists of environmentally friendly materials which can easily
be separated and recycled. We use the following packaging materials: wood,
cardboard, paper, and PE foil. For the disposal of the packaging material, we
recommend recycling and collection centres.