Service and Maintenance
77
Important: Note that the IP addresses on the PBX
have also been reset to factory settings. This means
you now need to reconfigure the network
configuration. See
. Exception: If the PBX
had been configured as a DHCP client (DHCP on),
this setting has been retained.
Performing an Immediate Firmware Update
Requirements
– Opened configuration manager (with an existing con-
nection to the PBX web server)
– Connection via broadband Internet access
(for example, a DSL connection)
– The address of the update server registered on the
page Administration
Server configuration:
www.auerswald-update.de
– The address of the DNS server registered on the
page Administration
Server configuration
– The number of the update server entered in the tele-
phones, if you would like to perform a firmware
update of the system telephones. See the telephone
manual.
Important: When performing a firmware update, the
PBX should be in the idle state.
Steps to Take
1.
Open the page Administration
Firmware update/
restart.
Note: Under Instant firmware update via update
server, enable the checkbox for COMfortel firmware
update if you would also like to perform a firmware
update for the system telephones.
2.
Click Update.
The “Status” LED and the “Power” LED are lit in
green during data transmission.
The “Status” LED and the “Power” LED light up in
red and orange for several seconds/minutes
during the restart. See also the table on
.
If both LEDs light up in green again, the restart is
complete and the PBX is ready for operation.
Further Steps
쑱
In order to use new features after a firmware update,
you normally need a new version of the operating
manual and the configuration manual. Both are
available per download from the support pages at the
Auerswald web site (Internet address:
www.auerswald.de).
Fig. 63: LEDs and buttons
Status
Reset
DEFAULT
Fig. 64: “Power” LED
Power
Содержание COMmander Basic.2
Страница 2: ......
Страница 51: ...Connecting ISDN End Devices 51 Fig 51 Connect the wall sockets to the internal UP0 port UAE8 IAE...
Страница 54: ...Connecting Other Devices 54 Fig 53 Casing socket assignment standpoint of the soldering connections...
Страница 83: ......
Страница 84: ...884285 05 04 11 For the sake of the environment 100 recycled paper...