Service and Maintenance
75
Shutting Down the PBX
Requirements
– Opened configuration manager (with an existing con-
nection to the PBX web server)
Steps to Take
1.
Open the page Administration
Firmware update/
restart.
2.
Click Power down.
3.
Click OK.
The “Power” LED lights up in red and the “Status”
LED lights up in green, which indicate that you
may now shut down the PBX. This state remains
active for 90 seconds.
Note: If you do not shut down the PBX, it restarts
after 90 seconds. The “Status” LED lights up in red. If
both LEDs light up in green again, the restart is
complete and the PBX is ready for operation.
Backing up configuration data on a data storage medium
Requirements
– Open configuration manager (existing connection to
the PBX web server)
Steps to take
1.
Open the page Administration
Data backup
Note: Under Read configuration data from the
PBX, additionally enable the checkbox Read net-
work settings if you want to read the network set-
tings from the PBX, as well.
Note: Under Read configuration data from the
PBX, additionally enable the checkbox Read PBX
data if you want to read the PBX data from the PBX,
as well.
2.
Click Read from PBX.
3.
Follow the instructions for your browser for saving the
file.
Restoring the configuration
Requirements
– Open configuration manager (existing connection to
the PBX web server)
– The configuration file previously saved on a data stor-
age medium
Steps to take
1.
Open the page Administration
Data backup
2.
Click Browse, and select the configuration file.
Note: Under Store configuration data in the PBX,
additionally enable the checkbox Apply network set-
tings if you want to apply the network settings, as
well.
Note: Under Store configuration data in the PBX,
additionally enable the checkbox Apply PBX data if
you want to apply the PBX data, as well.
3.
Click Store in the PBX.
If you have the status bar enabled in your
browser, for example, in Microsoft Internet Ex-
plorer, the progress is displayed.
As soon as the configuration has been saved in
the PBX, you will receive a message.
The “Power” LED blinks in orange during a re-
start.
If the LED lights up in green again, the restart is
complete and the PBX is ready for operation.
Inserting a Restoration Point for Configuration Data
Requirements
– Open configuration manager (existing connection to
the PBX web server)
Steps to take
1.
Open the page Administration
Data backup
2.
Click Insert restoration point.
3.
Click OK.
The restoration point is inserted. It is available in
the Configuration file list field under Restore
old configuration data.
Содержание COMmander Basic.2
Страница 2: ......
Страница 51: ...Connecting ISDN End Devices 51 Fig 51 Connect the wall sockets to the internal UP0 port UAE8 IAE...
Страница 54: ...Connecting Other Devices 54 Fig 53 Casing socket assignment standpoint of the soldering connections...
Страница 83: ......
Страница 84: ...884285 05 04 11 For the sake of the environment 100 recycled paper...