![auer 151201 Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/auer/151201/151201_installation-and-operating-instructions-manual_3015797035.webp)
-
INSTALLER
HIGH-TEMPERATURE ENERGY EFFICIENT HEAT PUMP
MANUAL
-
35
beep
yes
example
Enter
turn to
select
beep
• Press
to return to main screen.
See § "Appliance confi guration / Language".
5.3.5 - Selecting
summer / winter
mode
5.3.6 - Selecting the
LANGUage
5.3.7 -
BeeP
alert
5.3.8 - Accessing the
INST. MENU
Enter
Beep
inst. menu
beep
NO
The
summer / winter
mode enables you to switch modes manually:
Enter
Enter
Enter
summer
winter
automatic
summ./ wint.
Heating circuits are put into
standby mode
All installed circuits are active
Summer
and
winter
mode will
automatically switch according
to outside temperature and
after a time delay,
PAR.209
and
215
• This menu is for choosing a sound alert for each press of the dial.
• Press
then
and keep them held down
simultaneously for 3 seconds to access the installer menu.
N.B:
See §"Appliance Confi guration /
Installer Menu"
6.2.1 - Water circuit condensate drainage
6 - MAINTENANCE AND
REPAIRS
•In order to ensure the best performances
from your HRC
70
Heat Pump it should be
maintained.
• An annual maintenance check is recommended
on the hydraulic heating circuit, to be
carried out by a qualifi ed professional.
•Any work undertaken on the refrigerant
circuit MUST be carried out by a qualifi ed
professional with a category 1 certifi cate
of aptitude
•Switch the appliance off before opening it
6.1 - General information
6.2 - Hydraulic circuit maintenance
After the appliance has been running for a few days, it is advisable
to check that the water circuit is watertight and that condensates
are draining correctly.
N.B:
In case of maintenance work or decommissioning
an appliance, please respect all environmental
protection instructions concerning recovery,
recycling and disposal of consumables and
components.
Checking the water circuit consists of removing sludge, checking
the fi lters and stopping up any leaks that may have appeared.
Clean or replace clogged or dirty fi lters.
Check from time to time that the condensates are draining
properly:
- Remove the back panel
- Check the drainage hole for blockages
- Clean the condensates collection trough as deposits from air
intake may accumulate here.
- Clean the fl exible drainage hose
Case a : drainage from underneath
Cas b : drainage from the back
Check that the pressure relief valve is properly sealed. It should
not leak if the water pressure is under 2.5 bars.
Condensates collection
trough
Heater cable
Opening in
concrete slab
(case a)
Plastic cap (case a)
Membrane grommet (case b)
Pressure relief valve
Содержание 151201
Страница 8: ... INSTALLER HIGH TEMPERATURE ENERGY EFFICIENT HEAT PUMP MANUAL 8 ...
Страница 76: ... INSTALLER HIGH TEMPERATURE ENERGY EFFICIENT HEAT PUMP MANUAL 76 HRC70 Pilot electrical schematic diagram ...
Страница 77: ... INSTALLER HIGH TEMPERATURE ENERGY EFFICIENT HEAT PUMPMANUAL 77 Please see following pages for key ...
Страница 80: ... INSTALLER HIGH TEMPERATURE ENERGY EFFICIENT HEAT PUMP MANUAL 80 HRC70 Pilot internal wiring diagram ...
Страница 81: ... INSTALLER HIGH TEMPERATURE ENERGY EFFICIENT HEAT PUMPMANUAL 81 Please see previous pages for key ...
Страница 83: ... INSTALLER HIGH TEMPERATURE ENERGY EFFICIENT HEAT PUMPMANUAL 83 NOTES ...