INSTALLER
HIGH-TEMPERATURE ENERGY EFFICIENT HEAT PUMP
MANUAL
-
26
When the
"hp + elect"
or
"electric"
options are off ered, two
warning screens will appear:
then
elec. cable
size Ok?
no
size OK?
no
size OK?
yes
These screens serve to alert you to the fact that you are about to
activate the electrical back-up
The option you select will only be activated after you have
confi rmed it.
Is the HRC
70
Pilot cable wide enough?
Check in the § "Connecting the Pilot to
the power supply" section to ensure that the
diametre of the power supply cable is large
enough to support the strength of the electrical
current used by the appliance.
CONFIGURA.
Press the dial to access the
H
RC
70
Heat Pump
options
The "
Configuration"
sub-menu allows you to choose the
Heat Pump model as well as the type of circuit and type of
controls fi tted. The settings specifi c to each confi guration are
automatically adjusted by the software.
See the hydraulics diagrams in the appendices.
4.2.2 -
Configuration
of the HRC
70
Heat Pump
and circuits
Enter
hrc70
-
17
HP
hrc70
-
7
HP
To select 17kW HRC
70
Heat
Pump
To select the 25 - 20 - 35 - 7 or 11kW
HRC
70
Heat Pump
To confi rm the power of the
HRC
70
Heat Pump you are using
(7kW in the example shown
here)
4.2.2.1 - Heat Pump model
Enter
Enter
not used
C
-
1
no CTRL
A
-
1
RADIAToRs
C
-
1
thermosta.
a
-
1
floor heat.
C
-
1
INT. sens.
A
-
1
Connect one of the following ONLY:
- TEMPERATURE SENSOR with DISPLAY (Ref. 751009)
- ROOM THERMOSTAT (Ref. 710172)
Any other thermostat could cause a malfunction
and thus render the warranty null and void.
4.2.2.2 - Confi guring circuit 1
4.2.2.3 - Circuit 1 temperature control
To deactivate circuit 1(no
circuit or
permanent pool
( winter))
When there is no temperature
control for circuit 1 (heating
curve only)
For a radiator circuit installed
as circuit 1
When a thermostat (dry
contact) is controlling circuit 1
temperature
For an underfl oor heating
circuit (low temperature)
installed as circuit 1
When a temperature sensor
with display is controlling
circuit 1 temperature
Enter
Enter
Enter
Enter
Enter
Enter
NB:
If circuit 1 is an underfl oor heating circuit, it is
mandatory to fi t a temperature control.
Select the heat pump model that you have installed.
The diff erent models of heat pump appear in the following order:
HRC
70
- 17 / HRC
70
- 25 / HRC
70
- 20 / HRC
70
- 35
HRC
70
- 7 / HRC
70
- 11
Содержание 151201
Страница 8: ... INSTALLER HIGH TEMPERATURE ENERGY EFFICIENT HEAT PUMP MANUAL 8 ...
Страница 76: ... INSTALLER HIGH TEMPERATURE ENERGY EFFICIENT HEAT PUMP MANUAL 76 HRC70 Pilot electrical schematic diagram ...
Страница 77: ... INSTALLER HIGH TEMPERATURE ENERGY EFFICIENT HEAT PUMPMANUAL 77 Please see following pages for key ...
Страница 80: ... INSTALLER HIGH TEMPERATURE ENERGY EFFICIENT HEAT PUMP MANUAL 80 HRC70 Pilot internal wiring diagram ...
Страница 81: ... INSTALLER HIGH TEMPERATURE ENERGY EFFICIENT HEAT PUMPMANUAL 81 Please see previous pages for key ...
Страница 83: ... INSTALLER HIGH TEMPERATURE ENERGY EFFICIENT HEAT PUMPMANUAL 83 NOTES ...