To access the control data, such as pressure readings (in bars)
and all the temperatures read by the sensors (in °C), press and
hold down the dial for 3 seconds. While the dial is pressed down,
"display"
will appear on the screen.
• Turn the dial to the right to scroll through the display options
(the values given below are examples)
:
5.2 - Displaying the control values
Pt / opt
0
AMBIence
0
outside
-
35
°
C
heat curve
16.0
°
C
hp input
0.0
°
C
hp output
0.0
°
C
AIR hp
0.0
°
C
EVAPO
0.0
°
C
COMPRES
- -
1
0.0
°
C
COMPRES
- -
2
0.0
°
C
Pilot
-
50
°
C
PRESSure
-
2.0
shedding
0
N.B:
Temperature
display
If 2 heating zones are set, the
temperature is displayed for each
zone
N.B:
=If the heating zones
are controlled by a thermostat
rather than a room temperature
sensor, the display will show:
(heating request = 1 ;
comfort mode= 0)
AMBIeNCE 1
19.0
°
C
example
AMBIeNCE 1
1
example
• Press on the dial or the
key to return to the main screen.
• Press on the dial or the
key to return to the main screen.
5.3 - User Menu
N.B:
The screen only
displays information for the DHW
sensor if it has been set up. See §
"Installer menu / Confi guration"
N.B:
If the DHW zone is
controlled by an aquastat (heating
request = 1 ;
comfort mode = 0)
N.B:
If the swimming
pool kit is connected and
activated, both the temperature
and the fl ow rate (no fl ow rate
detected = 0; fl ow rate detected =
1) will be automatically displayed.
dhw senso.
53
°
C
example
AQUASTAT
0
example
swim. pool
23.5
°
C
example
pool flow
1
example
The User Menu allows you to access the settings for heating
modes, operating and stopping the appliance, and also to view
the temperatures in the installation.
• Press
to access the User Menu.
Enter
Enter
Enter
holidays
over ride
setting
Switch to holiday mode
Override heating mode in
progress
Setting target temperatures
Содержание 151201
Страница 8: ... INSTALLER HIGH TEMPERATURE ENERGY EFFICIENT HEAT PUMP MANUAL 8 ...
Страница 76: ... INSTALLER HIGH TEMPERATURE ENERGY EFFICIENT HEAT PUMP MANUAL 76 HRC70 Pilot electrical schematic diagram ...
Страница 77: ... INSTALLER HIGH TEMPERATURE ENERGY EFFICIENT HEAT PUMPMANUAL 77 Please see following pages for key ...
Страница 80: ... INSTALLER HIGH TEMPERATURE ENERGY EFFICIENT HEAT PUMP MANUAL 80 HRC70 Pilot internal wiring diagram ...
Страница 81: ... INSTALLER HIGH TEMPERATURE ENERGY EFFICIENT HEAT PUMPMANUAL 81 Please see previous pages for key ...
Страница 83: ... INSTALLER HIGH TEMPERATURE ENERGY EFFICIENT HEAT PUMPMANUAL 83 NOTES ...