background image

 

 

19

12 

Discard the All-in 

In accordance with the directive 2002/96/CE, the logo below indicates that the equipment concerned is not 
to be disposed of as ordinary waste at the end of its useable life. 
The equipment is to be delivered to a suitable depot that will dispose of the equipment in a proper way in 
accordance with the legislation on this subject, or to the supplier of new equipment in case of replacement. 
The owner of the equipment is responsible for proper disposal of the equipment. 
For further information we advise you to contact your local waste facility. 
 

 

Appropriate disposal of Waste of Electric and Electronic Equipment prevents unnecessary pollution 
of the environment and negative influence on general health. 

 
 

13 

Conditions of guarantee 

13.1  Liability 

 
1. 

We exclude any liability as far as it has not been arranged by law. 

2. 

Our liability will never exceed the amount of order. 

3. 

Subject to the general valid regulations of the law, we are not obliged to any compensation of 
damage of which kind ever, directly or indirectly, under which company damage, to movables and 
immovables or to persons, both to the opposite party as to third persons. 

4. 

In no way we are liable for damage arisen from or caused by the supplied or by the  

 

unsuitability of this for the purpose for which the opposite party has purchased the  

 

machine. 

 

13.2  Guarantee 

 
1. 

With due observance of the restrictions stated hereafter, we allow 12 months of guarantee to the 
products supplied by us. This guarantee is restricted to the occurring manufacture errors and does 
not imply interruptions caused by any form of wear spare parts subject to use. 

2. 

To spare parts or enclosures obtained from third persons we do not give longer guarantee than this 
third supplier does. 

3. 

Guarantee expires if the opposite party and/or third parties associated make improper use of the 
supplied. 

4. 

Guarantee also expires if the opposite party and/or third parties associated execute activities and/or 
modifications to the supplied. 

5. 

In case we replace spare parts to fulfill our guarantee engagement, the spare parts replaced 
become property of AUDION ELEKTRO B.V. 

6. 

In case the opposite party does not come up completely, partially or does not come up in time to the 
obligations arisen from the closed engagement between the parties, we are not obliged to guarantee 
as long as the situation continues. 

 

Содержание D 555 NH

Страница 1: ...AUDION ELEKTRO ALL IN SEALER D 555 NH MANUAL D555 NH ENG Rev06...

Страница 2: ...e hold responsible for eventual damage caused by specifications deviating from the standard model Although extreme care has been exercised during writing this manual AUDION ELEKTRO will not accept any...

Страница 3: ...10 8 1 Maintenance and adjusting ALL IN SEALER 11 8 2 Heating elements 12 8 2 1 Adjust heating plates 12 8 2 2 Replace heating elements 12 8 3 PTFE belts Fout Bladwijzer niet gedefinieerd 8 3 1 Adjust...

Страница 4: ...on the All in Check before the All in is put into operation whether the data on the identification plate corresponds with the Voltage V Power Rating W and Frequency Hz of the local power supply If the...

Страница 5: ...re control keeps the temperature fixed at the same level during operation The ALL IN SEALER is suitable for sealing ready to hand bags of Polyethylene PE Polypropylene PP thin PVC s and various lamina...

Страница 6: ...ly switches off to the standby mode 4 HEAT Turns the heater on off 5 FAN Turns the fan on off 6 MOTOR Turns the motor on off 7 Leds These leds indicate an active function 8 Display The display shows t...

Страница 7: ...tch fig 3 pos 1 must be at position O OFF 6 2 1 Adjusting height transport belt Adjust the height of the conveyor in relation to the seal unit The bag must be sealed at the half of the product height...

Страница 8: ...f the temperature deviation is more than 5 degrees from the adjusted value Make a couple of bags Re adjust if the bags are not sealed properly The seals are not tight The sealing temperature is too lo...

Страница 9: ...gency stop should only be used for emergencies and not for a temporary switch off or stop of the machine The emergency stop is operated by means of pushing the red button fig 4 on top of the machine A...

Страница 10: ...own or at least 10 minutes Only use spare parts supplied by Audion Elektro The maintenance schedule below is for normal use In case of intensive use or under extreme circumstances maintenance should b...

Страница 11: ...lt as far as possible from the ALL IN SEALER See fig 5 Remove the back cover 1 Open the upper front cover 2 Remove the lower front cover 3 Take care The heating plates can still be hot Before switchin...

Страница 12: ...s 8 2 2 Replace heating elements Remove the back cover Open the upper front cover Loosen the 3 screws fig 6 pos 1 to remove the complete moutingplate Disconnect the wiring of the heating elements Loos...

Страница 13: ...tes by rotating the handles above the plates clockwise fig 6 pos 5 Push the PTFE pulley on the righthand side to the left until you hear a click The pulley is now locked Place the new PTFE belt over t...

Страница 14: ...pos 2 to the right Replace the v belt Tension the v belt by sliding the shaft pos 2 to the left and fasten the nut Close all covers 8 5 Pressure roller The pressure roller applies an extra pressure on...

Страница 15: ...the transport belt if the belt touches the sides the tension on the belt is too high or too low Note Loosen the 4 locknuts fig 9 pos 1 before adjusting the tension Only adjust the tension when the be...

Страница 16: ...tor if necessary This factor will affect the motor output If set at e g 90 the motor will run slower and set at e g 110 the motor will run faster To perform a motor set up follow the next steps Select...

Страница 17: ...the right side in the middle The standard values are ON and 50Hz if the jumpers are removed 9 Technical data ALL IN SEALER D 555 NH Dimensions Weight Sealwidth Power rating Voltage Frequency Noise Se...

Страница 18: ...s in display E1 E2 E3 Wrong frequency 50 60Hz Loose wire to PT100 Short circuit in PT100 Check the frequency and adjust the jumper Check wiring and connections to the PT100 Replace PT100 Conveyor does...

Страница 19: ...nd immovables or to persons both to the opposite party as to third persons 4 In no way we are liable for damage arisen from or caused by the supplied or by the unsuitability of this for the purpose fo...

Страница 20: ...Appendix A1 14 Electrical circuit...

Страница 21: ...Appendix A2 Electrical circuit...

Страница 22: ...Appendix B1 15 Exploded views...

Страница 23: ...Appendix B2 Exploded views...

Страница 24: ...Appendix B3 Exploded views...

Страница 25: ...Appendix B4 Exploded views...

Страница 26: ...Appendix B5 Exploded views...

Страница 27: ...11 669 Trade reg Hilversum no 32057820 VAT no NL803873104B01 Our terms and conditions are deposited at the Chamber of Commerce in Hilversum Op alle overeenkomsten zijn van toepassing onze algemene lev...

Страница 28: ...AUDION ELEKTRO Hogeweyselaan 235 1382 JL Weesp Holland Tel 31 0 294 491717 Fax 31 0 294 491761 E mail export audion nl E mail holland audion nl Website www audion com Represented by...

Отзывы: