Version 5.8
233
September 2009
SIP User's Manual
6. Configuration Parameters Reference
6.3
Debugging and Diagnostics Parameters
This subsection describes the device's debugging and diagnostic parameters.
6.3.1
General Parameters
The general debugging and diagnostic parameters are described in the table below.
Table 6-14: General Debugging and Diagnostic Parameters
Parameter
Description
EMS: Enable Diagnostics
Checks the correct functionality of the different hardware components on
the device. On completion of the check, if the test fails, the device sends
information on the test results of each hardware component to the
Syslog server.
[EnableDiagnostics]
[0]
= Rapid and Enhanced self-test mode (default).
[1]
= Detailed self-test mode (full test of DSPs, PCM, Switch, LAN,
PHY and Flash).
[2]
For detailed information, refer to the
= A quicker version of the Detailed self-test mode (full test of
DSPs, PCM, Switch, LAN, PHY, but partial test of Flash).
Product Reference Manual
.
Note:
For this parameter to take effect, a device reset is required.
[WatchDogStatus]
[0]
= Disable device's watch dog.
[1]
= Enable device's watch dog (default).
Note:
For this parameter to take effect, a device reset is required.
[LifeLineType]
Defines the scenario upon which the Lifeline phone is activated. The
Lifeline phone is available on Port 1 of MP-11x FXS devices and on
ports 1 to 4 of MP-118 FXS/FXO devices. For FXS-only devices, FXS
Port 1 is connected to the POTS (Lifeline) phone as well as to the
PSTN/PBX (using a splitter cable). For combined FXS and FXO devices,
the FXS ports are provided with lifeline by their corresponding FXO ports
connected to the PSTN/PBX (i.e. FXO Port #5 provides lifeline to FXS
Port 1, FXO Port #6 provides lifeline to FXS Port 2, and so on). Upon
power outage and/or network failure, PSTN connectivity is maintained
for the FXS phone user.
[0]
= Lifeline is activated upon power failure (default).
[1]
= Lifeline is activated upon power failure or when the link is down
(physically disconnected).
[2]
= Lifeline is activated upon power failure, when the link is down, or
upon network failure (logical link disconnected).
Notes:
For this parameter to take effect, a device reset is required.
This parameter is only applicable to FXS interfaces.
To enable Lifeline switching on network failure, LAN watch dog must
be activated (EnableLANWatchDog set to 1).
For a detailed description on cabling the device for Lifeline, refer to
the device's Installation Manual.
Содержание Media Pack MP-112
Страница 1: ...Document LTRT 65412 September 2009 User s Manual Version 5 8...
Страница 2: ......
Страница 16: ...SIP User s Manual 16 Document LTRT 65412 MP 11x MP 124 Reader s Notes...
Страница 24: ...SIP User s Manual 24 Document LTRT 65412 MP 11x MP 124 Reader s Notes...
Страница 115: ...Version 5 8 115 September 2009 SIP User s Manual 3 Web Based Management Figure 3 68 Supplementary Services Page...
Страница 188: ...SIP User s Manual 188 Document LTRT 65412 MP 11x MP 124 Reader s Notes...
Страница 364: ...SIP User s Manual 364 Document LTRT 65412 MP 11x MP 124 Reader s Notes...
Страница 366: ...SIP User s Manual 366 Document LTRT 65412 MP 11x MP 124 Reader s Note...
Страница 472: ...SIP User s Manual 472 Document LTRT 65412 MP 11x MP 124 Reader s Notes...
Страница 474: ...SIP User s Manual 474 Document LTRT 65412 MP 11x MP 124 Reader s Notes...
Страница 482: ...SIP User s Manual 482 Document LTRT 65412 MP 11x MP 124 Reader s Notes...
Страница 486: ...User s Manual Version 5 8 www audiocodes com...