![Audio Design Associates Suite 16 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/audio-design-associates/suite-16/suite-16_system-design-and-technical-documentation_3008134008.webp)
- 7 -
1 2 3 4 5 6 7 8
TO 9 PIN "D"
DELTA-88
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1000 WATTS
MAX TOTAL
Set Shunting Pins To Engage AC With Zone Or Source Numbers 1-8
120-240 VAC
50-60 Hz
QUAD AC CONTROLLER
ACC-48
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
1.
Delta-88 9 Pin "D" programmed for source AC control. - Set one shunting
pin per AC outlet according to source inputs. Set 3 pins for MT-3000.
2.
Delta-88 9 Pin "D" programmed for zone AC control. - Set one shunting
pen per AC outlet according to zone numbers. Set all shunting pins on
one AC Outlet for All-On source AC control when not using an ACC-3000.
3
4
2
1
1 2 3 4 5 6 7 8
TO 9 PIN "D"
DELTA-88
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1000 WATTS
MAX TOTAL
Set Shunting Pins To Engage AC With Zone Or Source Numbers 1-8
120-240 VAC
50-60 Hz
QUAD AC CONTROLLER
ACC-48
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
1.
Delta-88 9 Pin "D" programmed for source AC control. - Set one shunting
pin per AC outlet according to source inputs. Set 3 pins for MT-3000.
2.
Delta-88 9 Pin "D" programmed for zone AC control. - Set one shunting
pen per AC outlet according to zone numbers. Set all shunting pins on
one AC Outlet for All-On source AC control when not using an ACC-3000.
3
4
2
1
OUTPUT
LEVEL
ANTENNA
AUDIO OUTPUT
L
R
TUNER 3
OUTPUT
LEVEL
ANTENNA
AUDIO OUTPUT
L
R
TUNER 2
OUTPUT
LEVEL
ANTENNA
AUDIO OUTPUT
L
R
TUNER 1
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1
This device may not cause harmful interference.
2
This device must accept any interference
received, including interference that may cause
undesired operation.
T
RINITY
T
RIPLE
T
UNER
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
BUS
®
• ICC - I
NTERACTIVE
C
OMPONENT
C
OMMUNICATION
•
AC INPUT
115V 2/10A S.B.
230V 1/10 AS.B.
ADA Bus™
1 2 3 4
CAUTION: DISCONNECT SUPPLY
CORD BEFORE SERVICING.
ATTENTION: DEBRANCHER AVANT
LE DEPANNAGE.
115 V
115V
230V
Voltage Selector
The Trinity Does Not
Require a BI-3000.
IR Flasher
Input
11
5 V
The ACC-48 features jumper pins (shunting pins) that determine which sources the outlet will
activate with. Several jumper pins can be inserted for any one outlet. In the case of the Trinity
Triple Tuner, the Trinity has only one AC cord, even though it acts like three components to
the system. As such, three jumper pins would be inserted into the Trinity Tuner’s ACC-48
outlet such that, whenever any of the three tuner modules is accessed, the tuner will get AC
and engage.