![Audio Design Associates Suite 16 Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/audio-design-associates/suite-16/suite-16_system-design-and-technical-documentation_3008134061.webp)
- 60 -
Paging Control
The paging control tab permits you to simulate paging triggers.
The first six triggers are only controlled serially. As such, a control code needs to be issued in
order to activate triggers 1 through 6.
Paging group 7 is the audio sensing trigger. The sensitivity of this trigger is set on the front of
the A-16 module by removing the plexiglass panel. Because a page will always cause the
audio to be sensed, if you desire to defeat this trigger en-
tirely (perhaps because you are only using serial triggers),
this page has an option which permits you to disable pag-
ing group 7 entirely.
Paging group 8 is the low voltage trigger paging group,
again hardwired directly to the back of the A-16 module.
When engaging any of the paging groups, you can opt to
remove a room from being paged by selecting the page all
except the desired room number pull down window.
You can also activate paging to a single room on this
page. For direct paging, select the room number and
then press the page button.
It is important to remember that when a page is acti-
vated, you must turn paging off before rooms return
to their previous state. Once a page is initiated, it will
remain on until it is turned off. In the case of triggers
7 & 8, the paging turns off when the trigger is removed.
In the case of paging group triggers 1-6 or room to
room paging, you must turn all paging off.
If paging is on, there are two ways to turn paging off. If a room is being paged, selecting an
alternate source input will turn the paging off for just that room. To reset paging for the entire
system other than by issuing a serial control to do so, you will need to reset the system by
turning the master power switch off on the front of the Suite 16.