- 48 -
RS-232 Connections for PC’s & Control Systems
The AVP-16 chassis features two RS-232 ports, one on the front of the chassis and a second
one on the rear panel. These two RS-232 ports are in parallel. As such only one port can be
used at any one time. If you have a PC or external control system connected to the rear panel
RS-232 port, the front panel port will not be functional. The same is true if you have the front
port active, then the rear panel port will not be active.
Ideally, you want to leave either the front panel (or perhaps the rear panel) port available for
connection of a PC. This will permit you to connect your lap top PC to the Suite-16 System so
that you can use the two following PC based programs, the Keypad Uploader and Suite 16
Tester.
The Keypad Uploader program permits you to program MC-5000, MC-6000, MC-3000, MC-
3800, MC-3000 OD and MC-3800 OD keypads without having to enter the keypads program
steps. The Suite-16 Tester program is most useful for system set up. In most cases, you will
need to use a PC to fully access all the feature sets of Suite 16. As such, this program and its
ability to connect to the AVP-16 is essential.
Communication Settings
While the baud rate on the Suite 16 is adjustable between 1200 and 19200 baud, the typical
setting used is
19200 baud.
Other settings are
8 Data Bits, 1 Stop Bit, & No Parity.
ISO-232 & External Control Systems
If you are also controlling the Suite 16 System
from an external control system (i.e. AMX or
Crestron), ADA strongly suggests adding an
ISO-232 to the system. In addition to leaving
either the front or rear panel RS-232 jack open
for your PC, the ISO-232 provides electrical
isolation that is not internal to the AVP-16’s RS-
232 ports. This isolation will be useful in help-
ing to eliminate ground loops. The ISO-232
can connect directly to any open ADA Bus port
on the system wire harness or if no other ADA
Bus components are used in the system, in-
cluding any ADA keypads, directly into the ADA
Bus jack on the AVP-16.
RS-232 Cable
The connection of PC or Control Sys-
tem to an ADA RS-232 port requires a
simple straight through 9-pin “D” style
RS-232 cable. You should not use a
null-modem or cross-over cable. If you
use an alternate type of cable, you will
most likely not get communication, in the
form of feedback or control to occur.
1/2 ASB
115V~
1/4 ASB
230V~
115V~/60Hz 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
230V
115V
1 Gnd
2 Fdbk
3 Cntrl
4 +V
ADA BusÆ
Network Control I/O
Main
AC
Input
Switch
AC
(10A)
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
AVP-16 MR Controller
115 V
1
L
R
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
P-16
P-16 Preamplifier Module
Zones 1- 6 & 7-12
+12VDC Outputs
Gnd
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
In 1/7
In 2/8
In 5/11
In 6/12
TO PTM-1225/1260
Zones 1-6
Zones 7-12
In 4/10
In 3/9
VIDEO INPUTS
EXPANSION PORTS
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
V-
16
V-16 Video I/O Module
Output Triggers
Input Triggers
+12VDC Outputs
Gnd
Out 8/16
Programmed Video
Input Triggers
5-24V AC DC
Gnd
(-)
1
(+)
2
(+)
3
(+)
4
(+)
Out 1/9
Out 2/10
Out 5/13
Out 6/14
Out 1-8
Out 9-16
Out 7/15
Out 4/12
Out 3/11
1
L
R
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A-16
A-16 Audio Input Module
Input Triggers
Paging Input/Trigger
+12VDC Outputs
Gnd
In 8/16
Balanced
Audio Page
Input (600
)
Trigger
5-24V
AC DC
1
Com
2
(+)
3
(-)
4
(+)
5
(-)
In 1/9
In 2/10
In 5/13
In 6/14
In 1-8
In 9-16
In 7/15
In 4/12
In 3/11
1 2 3 4
WH-2000
J1
J2
J3
J4
J5
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
ADA BUS
ISO-232
1 2 3 4
RS-232
Normal
Reverse
(TuneBase)
To RS-232 Control
System or AMX or
Crestron Control System
WH-2000
ADA Bus to WH-2000 J1
Use either front or rear panel RS-232 port
to connect to your PC. Do not use both at same time.
ISO-232
ADA Bus To
RS-232 Converter
AVP-16
POWER
RS-232