![Audio Design Associates Suite 16 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/audio-design-associates/suite-16/suite-16_system-design-and-technical-documentation_3008134023.webp)
- 22 -
1/2 ASB
115V~
1/4 ASB
230V~
115V~/60Hz • 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
230V
115V
1 Gnd
2 Fdbk
3 Cntrl
4 +V
ADA Bus®
Network Control I/O
Main
AC
Input
Switch
AC
(10A)
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
AVP-16 MR Controller
115 V
1
L
R
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
P-16
P-16 • Preamplifier Module
Zones 1- 6 & 7-12
+12VDC Outputs
Gnd
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
In 1/7
In 2/8
In 5/11
In 6/12
TO PTM-1225/1260
Zones 1-6
Zones 7-12
In 4/10
In 3/9
VIDEO INPUTS
EXPANSION PORTS
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
V-
16
V-16 • Video I/O Module
Output Triggers
Input Triggers
+12VDC Outputs
Gnd
Out 8/16
Programmed Video
Input Triggers
5-24V AC•DC
Gnd
(+)
1
(+)
2
(+)
3
(+)
4
(+)
Out 1/9
Out 2/10
Out 5/13
Out 6/14
Out 1-8
Out 9-16
Out 7/15
Out 4/12
Out 3/11
1
L
R
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A-16
A-16 • Audio Input Module
Input Triggers
Paging Input/Trigger
+12VDC Outputs
Gnd
In 8/16
Balanced
Audio Page
Input (600
Ω
)
Trigger
5-24V
AC•DC
1
Com
2
(+)
3
(-)
4
(+)
5
(-)
In 1/9
In 2/10
In 5/13
In 6/14
In 1-8
In 9-16
In 7/15
In 4/12
In 3/11
Basic Video Setup - One A-16, One P-16, and One V-16
This configuration adds video to the basic 16 audio sources to 16 zone configuration. Be-
cause the video card can have outputs either track or not track the 16 audio inputs, one can
treat the 16 video sources as additional inputs and outputs. For example, out of the 16 audio
sources, only 10 have a video signal. That would leave 6 video inputs available for non-audio
video input devices such as cameras.
1/2 ASB
115V~
1/4 ASB
230V~
115V~/60Hz • 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
230V
115V
1 Gnd
2 Fdbk
3 Cntrl
4 +V
ADA Bus®
Network Control I/O
Main
AC
Input
Switch
AC
(10A)
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
AVP-16 MR Controller
115 V
1
L
R
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
P-16
P-16 • Preamplifier Module
Zones 1- 6 & 7-12
+12VDC Outputs
Gnd
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
In 1/7
In 2/8
In 5/11
In 6/12
TO PTM-1225/1260
Zones 1-6
Zones 7-12
In 4/10
In 3/9
1
L
R
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A-16
A-16 • Audio Input Module
Input Triggers
Paging Input/Trigger
+12VDC Outputs
Gnd
In 8/16
Balanced
Audio Page
Input (600
Ω
)
Trigger
5-24V
AC•DC
1
Com
2
(+)
3
(-)
4
(+)
5
(-)
In 1/9
In 2/10
In 5/13
In 6/14
In 1-8
In 9-16
In 7/15
In 4/12
In 3/11
1/2 ASB
115V~
1/4 ASB
230V~
115V~/60Hz • 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
230V
115V
1 Gnd
2 Fdbk
3 Cntrl
4 +V
ADA Bus®
Network Control I/O
Main
AC
Input
Switch
AC
(10A)
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
AVP-16 MR Controller
115 V
1
L
R
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
P-16
P-16 • Preamplifier Module
Zones 1- 6 & 7-12
+12VDC Outputs
Gnd
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
In 1/7
In 2/8
In 5/11
In 6/12
TO PTM-1225/1260
Zones 1-6
Zones 7-12
In 4/10
In 3/9
1
L
R
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
P-16
P-16 • Preamplifier Module
Zones 1- 6 & 7-12
+12VDC Outputs
Gnd
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
In 1/7
In 2/8
In 5/11
In 6/12
TO PTM-1225/1260
Zones 1-6
Zones 7-12
In 4/10
In 3/9
1
L
R
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A-16
A-16 • Audio Input Module
Input Triggers
Paging Input/Trigger
+12VDC Outputs
Gnd
In 8/16
Balanced
Audio Page
Input (600
Ω
)
Trigger
5-24V
AC•DC
1
Com
2
(+)
3
(-)
4
(+)
5
(-)
In 1/9
In 2/10
In 5/13
In 6/14
In 1-8
In 9-16
In 7/15
In 4/12
In 3/11
Double Audio Setup - One A-16 & Two P-16s
This configuration adds an additional 16 zones for a total of 16 audio components to 32 audio
zones.
AVP-16 Configuration Options
The AVP-16 is the Suite 16 chassis that can house up to three cards. As both the A-16, P-16,
and V-16 are designed to be interchangeable, here are some options regarding configuration
of the primary AVP-16.
Basic Setup - One A-16 and One P-16
This configuration is the most basic of all Suite 16 options in which 16 audio components are
routed to 16 audio zones.