![Audio Design Associates Suite 16 Скачать руководство пользователя страница 75](http://html1.mh-extra.com/html/audio-design-associates/suite-16/suite-16_system-design-and-technical-documentation_3008134075.webp)
- 74 -
PARTY SET 1-4
Allows any given room to become a “member” of party 1-4
EXAMPLE
‘SPTS1R01<cr>
set room 1 to be a member of party 1
Feedback
‘AXPTS1R01<cr>
Feedback Request
‘GPTS1R01<cr>
Feedback
‘AXPTS1R01<cr>
or room 1 is in party 1
‘AXPTC1R01
room 1 is not in party 1
PARTY CLEAR 1-4
Clears a given room from party 1-4
EXAMPLE
‘SPTC1R01<cr>
clear room 1 from party 1
Feedback
‘AXPTC1R01<cr>
Feedback Request
‘GPTC1R01<cr>
Feedback
‘AXPTS1R01<cr>
or room 1 is in party 1
‘AXPTC1R01
room 1 is not in party 1
PARTY 1-4
The party command is a global function of 4 pre-selected groups of rooms. The room mem-
bers of each party are turned on and set to the same source input in the command string. The
2 characters after the G specify the input to set the party to in the range 01 to 16.
EXAMPLE
‘SPTY1G01<cr>
set all members of party 1 to input 1
Feedbackcurrent room inputs for each room in party ‘AXAD##R##<cr>
PAGING OVERVIEW
The paging function of the preamplifier actually has 9 ways to accomplish paging. There are
8 paging groups any room can become a “member” of. Each room also has a serial com-
mand to pre-set a paging level for that room. When a room is paged all balance and tone
controls are nulled and the preset page volume is set. After completion of page, control
resume their setting previous to the page. If the room had been turned off it will turn on for the
page and then turn off again when the page is completed. The first 6 groups use serial
controlled paging. Group 7 is the auto paging mode and is hardware controlled. This is
controlled by an audio level detector. When an audio signal applied to the auto page input
exceeds a predetermined level, all members that are part of group 7 are paged. In the event
of interference or noise inadvertently activating auto page, there is a serial command which
can activate or deactivate the auto page mode. Group 8 is another hardware controlled
paging mode. This is a simple dry contact input that will page members of group 8. The ninth
method of paging is the room to room page. With this command any room can be discretely
paged. Only one page can occur at one time. The method of page activation must also be
used to cancel the page. For example, a manual page by contact closure must be cancelled
by opening the contact. An auto page by audio level activation must be cancelled by the level
being below the trigger threshold. Any serial controlled page must be cancelled by a serial
command. For serial command page groups 1-6, if the room initiating the page is part of the
group, it will be omitted so no audio feedback occurs. Functions are as follows: