GOLDENEAGLE TV 6.0.x user manual
– 07/2012
Page 72
Head Office
: Parc d’activites Kennedy - 20, avenue Neil Armstrong – F-33700 Bordeaux-Merignac (France)
Tel +33 (0)5 57 928 928
– Fax +33 (0)5 57 928 929 –
–
www.audemat.com
12.2. Relay output module
Please refer to the ScriptEasy manual for more information on I/O management.
This module provides 8 SPDT relays. Each relay has one com input (common) and two outputs: NC
(normally closed) and NO (normally opened).
Schematic diagram:
When the relay is not in use, com is linked to the NC output.
When the relay is activated, com is linked to the NO output.
If your unit reboots, com is then linked to the NC output.
Practical examples:
1. The relay can be used like an on-off switch to make a contact between the common and one of the
outputs (NC or NO).
2. It is also possible to connect a power supply to the common (for example the +12 V power supply
available on pin 13) and to switch this power supply between the NC and the NO output.
NC (Normally closed)
NO (Normally open)
COM
RELAY (x8)