GOLDENEAGLE TV 6.0.x user manual
– 07/2012
Page 45
Head Office
: Parc d’activites Kennedy - 20, avenue Neil Armstrong – F-33700 Bordeaux-Merignac (France)
Tel +33 (0)5 57 928 928
– Fax +33 (0)5 57 928 929 –
–
www.audemat.com
7.2.
Channel configuration
7.2.1. Basic Configuration
To access it, select a station in the list and select
the ‘Basic Configuration’ tab.
The Station configuration window is where you enter the basic information about the stations you want the
unit to receive and analyze. Select the program you wish to configure in the list
(1)
. Note: colors indicate the
monitoring status for each channel (see below).
The name may be modified and you may add optional information about the transmitter and network if
desired
(2)
.
You may also set or change the monitoring status of the station in the ‘Monitoring Configuration’ section
(3)
.
‘Active Monitoring’
is a cyclical scanning of the station, with alarms for technical personnel.
The channel appears on a green background in the list.
‘Measure without alarm’
will scan the station and keep track of the readings, but will not send
alerts on out-of tolerance conditions. The channel appears on a blue background in the list.
Finally, if you do not want this particular station to be a part of the regular monitoring cycle,
select the
‘Standby’
box. This will leave the station configured, so that you may manually
monitor when you choose, but the GOLDENEAGLE TV will not generate alarms, automatically
scan that station or record its measurements on a regular basis. The channel appears on a grey
background in the list.
You may also limit the time during which the station is monitored on a daily basis
(4)
. If the box is left
unchecked, it will be monitored 24 h a day; if not it will be limited to the set period.
3
1
2
4
5
5