GOLDENEAGLE TV 6.0.x user manual
– 07/2012
Page 61
Head Office
: Parc d’activites Kennedy - 20, avenue Neil Armstrong – F-33700 Bordeaux-Merignac (France)
Tel +33 (0)5 57 928 928
– Fax +33 (0)5 57 928 929 –
–
www.audemat.com
Place the cursor over a bar to display station information.
In addition to monitoring configured stations, the GOLDENEAGLE TV can automatically scan the band at
regular intervals or daily at the same time. The triggering mode can be:
Disabled.
Interval: scanning is launched at regular intervals ranging between 1 min and 24 h.
Time: scanning is launched daily at a time set by the user.
The unit records the minimum and maximum RF levels of the carriers and triggers an alarm (if validated by
the user) when a RF level change is detected. The minimum RF threshold and the triggering difference are
user-defined.
Before validating the scan alarm function, a reference scan must be carried out by the unit. Click
“New
Refere
nce Scan” to start that scan, or set the current scan as reference with “”Set Current Scan to
Reference”.
In this section, you may also:
Clear min and max scans.
Run a new current scan. The channel range is user-defined.
Monitoring is never interrupted when scanning is in progress.