The redirection does not deactivate or turn off the default ports.
It only ‘clones’ or duplicates their
functions on the ports designated. External methods must be used to block any undesired ports from
the network.
To configure the unit as a router on a local network:
This function allows a user to communicate with all of the equipment on the local network shared by the
GOLDENEAGLE (Ethernet) from a PC connected to the GOLDENEAGLE by modem (PPP).
To configure this function, select “Enabled” on the “Router mode” line.
The input and output interfaces of the router can be configured by the options « Public interface » (Input) and
« Private Interface » (output).
Once the configuration is done, lock it in by clicking on “update”. Then click the “Activate new configuration”
button at the top of the page.
Click on the
“Activate new configuration” button every time a section is modified.