GOLDENEAGLE TV 6.0.x user manual
– 07/2012
Page 22
Head Office
: Parc d’activites Kennedy - 20, avenue Neil Armstrong – F-33700 Bordeaux-Merignac (France)
Tel +33 (0)5 57 928 928
– Fax +33 (0)5 57 928 929 –
–
www.audemat.com
o
SerialNumber: unit serial number
o
VersionSoftware: embedded software number version
o
trapsSequenceNumber
: trap sequence number (this value is incremented for each new
trap)
When an alarm is triggered, a TRAP is sent with the following values:
sysSystemType STRING / Equipment type
sysSerialNumber: Serial number
sysVersionSoftware: Version
trapsSequenceNumber: Trap number
trapsDefinitionmonitoringValueschannel: TV channel
trapsDefinitionmonitoringValuesstationId: Station ID
trapsDefinitionmonitoringValuesstationName: Station name
trapsDefinitionmonitoringValuesalarmStatus: State of the alarm (see below)
trapsDefinitionmonitoringValueserrorDateTime: Error starting date
trapsDefinitionmonitoringValueseventStartDateTime: Alarm date
trapsDefinitionmonitoringValuesseverity: Severity
trapsDefinitionmonitoringValuesreadValue: Read value
trapsDefinitionmonitoringValuesreferenceValue: Reference value
trapsDefinitionmonitoringValuestransmitterName: Transmitter name
trapsDefinitionmonitoringValuesnetworkName: Network name
trapsDefinitionmonitoringValuesdescription: Read and reference values as string
When the alarm is over, the same trap is sent with alarmStatus = 2, and the end time in errorDateTime.
Case of alarms ‘closed by hierarchy’
When an alarm with a high hierarchical level is triggered, the state for each lower hierarchical level alarm
changes
to ‘CLOSED’ and a notification for ‘closed by hierarchy’ is sent. As an example, if an RFHIGH alarm
is active and the RFLOW2 alarm gets triggered, an RFHIGH trap is sent with an alarmStatus value of 3
(closed by hierarchy).
Inversely, when the high level alarm ends,
the lower level tests that were ‘CLOSED’ return to ‘ALARM’ status
and traps are sent with alarmStatus values of 4 (alarm reopened).
The alarmStatus field value can be:
o
1 : Alarm beginning
o
2 : Alarm ending
o
3 : Alarm closed by a higher hierarchical level alarm
o
4 : Alarm reopened (the higher hierarchical level alarm is over)
o
5 : Intermittent alarm
o
6 : Information (notifications with no beginning nor end)