16/31
00000000000000000000
00000000000000000000
>Step 1 SmkrTemp 250
1- End i ng by Fd Temp
00000000000000000000
00000000000000000000
> Back
Step 1 SmkrTemp 250
00000000000000000000
00000000000000000000
Smkr 137 Food 122
Set 250 Probe3 670
Step 1 SmkrTemp 250
Step 1 SmkrTemp 120
SE T
SE T
/
SE T
00000000000000000000
00000000000000000000
>Prog S tatus Stop
Step 1 SmkrTemp 250
Prog S tatus Stop
Prog S tatus Start
SE T
/
SE T
Figure 18A. Flow chart of how to use Program Status & Control function.
4.1.4 Switch between single-step mode and multi-step mode
To switch between single-step mode and multi-step mode, go to Parameter Setting mode
by holding the SET key, and then go to “
System Config
” menu, find parameter “
Program
Mode
”, then change it to “
ON
” (for multi-step mode) or “
OFF
” (for single-step mode). By
default, the controller is set to multi-step mode “
ON
”. Please see the flow chart in Figure
20 for how to access this parameter from the controller.
00000000000000000000
00000000000000000000
> System Con f i g
Back
00000000000000000000
00000000000000000000
>Program Mode ON
Output Hi L im i t 100
Program Mode
ON
Program Mode
OFF
SE T
SE T
/
SE T
00000000000000000000
00000000000000000000
>Back
Program Mode ON
SET
Multi-step Mode
Single-step Mode
00000000000000000000
00000000000000000000
Smkr 137 Food 122
Set 250 Probe3 270
SE T
Press & Hold
Figure 20. How to switch between programmable mode and single-step mode
5. Controller parameter setup.
To access the parameters, press and hold SET key for about 2 seconds. Parameters are
divided into two groups: “
Control Config
” and “
System Config
”.