“Step: 1” and the current target cabinet temperature in the top line. A curser “>” will be
shown on the left indicating which line will be selected. Press SET key once, the current
set temperature should start blinking. Use
▲
and
▼
keys to change the set
temperature. When finished, press the SET again to confirm the change. That number
will stop blinking. Press the Timer/Back key to exit the menu. Or use
▲
or
▼
key to
scroll to “Back” and then press SET key to exit. The display will return to the normal
display mode if no key is
pressed in 15 seconds.
00000000000000000000
00000000000000000000
>Step 1 SmkrTemp 250
Back
00000000000000000000
00000000000000000000
Smkr 137 Food 122
Set 250 Probe3 270
00000000000000000000
00000000000000000000
>Step 1 SmkrTemp 250
Back
00000000000000000000
00000000000000000000
Step 1 SmkrTemp 250
> Back
SET
Press
SET
Press
Use
or
keys to adjust
set pit temp. Press SET key
to confirm.
Press
SET
Figure 19. How to change the set temperature in single-step mode.
4.1.3 Program Status & Control
(for firmware version 1.7.4 or newer)
User can check or change current program running status by this parameter. It can be
used to stop/start the program, or jump to a different step. This parameter is under the
Cooking Profile menu as stated in section 4.1. Parameter name showing on the
controller’s display is
Prog Status.
Available options for this parameter are: Stop, Start,
Step 1 ~ 6, Back.
When pressing SET button momentarily to enter Cooking Profile menu, it will display
Prog Status
on the left top, and current step number or stopped status on the right top.
Press SET button again, then user can change its options to start/stop the program or
jump steps. Press SET button again to confirm the change. See option definition and
flow chart below.
Option definition:
Stop:
Stop the current cooking program.
Start:
Start the cooking program from Step 1.
Step 1 ~ 6:
Jump to specific step. For example, if user selects Step 3, controller will skip
Step 1 & 2, and run rest steps starting at Step 3. If the controller program is stopped,
selecting those options will also exit stopped mode. Step 1 ~ 6 options are available for
multi-step mode only. For single-step mode, only
Step 1
is available.
Back: