23/33
important to you.
Go to the Parameter Setting mode by holding the SET key and then go to “
Control
Setting
” menu, find parameter “
Save Recipe
”, and press SET key again so you can
change its value. If you press
▲
or
▼
key repeatedly, you will see “Back”, “B1”, “B2”,
“C1”, “C2”, “F1”, “F2” one by one. Locate the recipe you want to save to, then press SET
key to confirm.
7.2 System Configurations
Parameters related device configurations, which are not often used during the smoking
process, are listed under “
System Config
” menu. Details of each parameters are listed
in Table 3. The flow chart in Figure 27 shows the operations of accessing and adjusting
the parameters in “
System Config
”.
Table 3. Parameters in System Config menu.
Name
Description
Range
Initial Note
Program Mode
Multi-Step Program
ON, OFF
ON
12
Output Hi Limit
Output High Limit %
0 - 100
100
13
Output Lo Limit
Output Low Limit %
0 - 100
0
13
Temp Unit
Temp Unit (°C or °F)
C, F
F
14
Probe1 Offset
Probe 1 (Cabinet Probe) Offset
-9 - 99
0
15
Probe2 Offset
Probe 2 (Food Internal Probe) Offset
-9 - 99
0
15
Probe3 Offset
Probe 3 Offset
-9 - 99
0
15
Probe3 Enabled
Probe 3 Readout Option
Yes, No
Yes
16
P3 ALM-TYPE
Probe 3 Alarm Type Option
ABS, DEV
ABS
17
P3 ALM-CTL
Probe 3 Alarm Output Control Option
ALM, OUT-PAU, BOTH
ALM
18
Step End Alarm
Step Ending Alarm
ON, OFF
ON
19
Backlight Level
LCD Backlight Level
0 - 10
10
20
BUZZ
Built-in Buzzer Option
ON, OFF
ON
21
Data Interval
Data Logging Sampling Interval (App)
1min - 5min
1min
22
nFlt
Power Line Digital Filter
Auto, A, B
Auto
23
Password
Device Access Password (App)
100 - 999
777
24
Factory Reset
Factory Reset
Yes, No
No
25
Back
Back to Upper Level Menu