Prog Status

 on the left top and the current step number or stopped status on the right 

top. Press the SET button again, then user can change its options to start/stop the 
program or jump steps. Press the SET button again to confirm the change. See option 
definition and flow chart below.   
 
Option definition: 

Stop:

 Stop the current cooking program.   

Start:

 Start the cooking program from Step 1. 

Step 1 ~ 6:

 Jump to specific step. For example, if user selects Step 3, controller will skip 

Step 1 & 2, and run rest steps starting at Step 3. If the controller program is stopped, 
selecting those options will also exit stopped mode. Step 1 ~ 6 options are available for 
multi-step mode only. For single-step mode, only 

Step 1

 is available.   

Back:

 Go back to upper level. Parameter is unchanged. 

00000000000000000000
00000000000000000000

>Step    1   SmkrTemp  250
   1- End i ng   by   Fd   Temp

00000000000000000000
00000000000000000000

> Back
   Step    1   SmkrTemp  250

00000000000000000000
00000000000000000000

Smkr    137            Food    122
Set       250      Probe3   670 

Step    1   SmkrTemp  250

Step    1   SmkrTemp  120

SE T

 

 

SE T

 

 

/

SE T

00000000000000000000
00000000000000000000

>Prog   S tatus             Stop
  Step    1   SmkrTemp  250

Prog   S tatus             Stop

Prog   S tatus            Start

SE T

 

 

 

 

/

SE T

 

Figure 18A. Flow chart of how to use Program Status & Control function. 

 

 

4.1.4 Switch between single-step mode and multi-step mode 

To switch between single-step mode and multi-step mode, go to Parameter Setting mode 
by  holding  the  SET  key,  and  then  go  to  “

System  Config

”  menu,  find  parameter 

Program Mode

”, then change it to “

ON

” (for multi-step mode) or “

OFF

” (for single-step 

mode).  By  default,  the  controller  is  set  to  multi-step  mode  “

ON

”.  Please  see  the  flow 

chart in Figure 20 for how to access this parameter from the controller.         

Содержание AW-WST1510H-W

Страница 1: ...plug and play controller is rather simple to operate the process involves high temperature and high wattage appliances and your safety is our number one priority SAFETY WARNINGS This controller is de...

Страница 2: ...device Built in optically isolated solid state relay with zero voltage crossing switching Sensor type PT1000 RTD sensor Timer range 6 steps with 23h59m for each step Temperature resolution 1 C or 1 F...

Страница 3: ...erator indicator Red This indicator has two functions When blinking the temperature alarm is triggered The LCD display will simultaneously flash the alarm notification at same time When this indicator...

Страница 4: ...scroll up the menu or mute the buzzer Figure 2 Back Panel Up to three temperature probes can be used with this controller and they need to be plugged in P1 P2 and P3 sockets on the right of the back...

Страница 5: ...s are based on Bradley smokers For other brand smokers if your smoker comes with an analog heat level dial you can directly hook up the power cord of your smoker to the heater output outlet on the bac...

Страница 6: ...1 Connection for Bradley Original Smoker with control of the smoker generator a When powering your controller you should use the power cord that came with the Bradley Smoker b Connecting the controlle...

Страница 7: ...the Bradley Smoker Tower with the power cord that came with the Auber controller Auber Controller Smoke Generator Smoker Tower Probe 1 Cabinet Temp Probe 2 Internal Temp Cable A Cable B To Power Outl...

Страница 8: ...nerator should be connected directly to the wall outlet In addition the controller output must be connected with the smoke tower Auber Controller Smoke Generator Smoker Tower Probe 1 Cabinet Temp Prob...

Страница 9: ...00000000000000000000 00000000000000000000 1 Fd Temp 195 Step 2 SmkrTemp 200 Press Momentarily 00000000000000000000 00000000000000000000 Step 1 Runtime 0 02 Ends at 195 00000000000000000000 0000000000...

Страница 10: ...more information or to return back to normal display mode Three display possibilities 00000000000000000000 00000000000000000000 Total Runtime 0 03 Power Output 100 Press Momentarily Press Momentarily...

Страница 11: ...splay mode Press Momentarily 00000000000000000000 00000000000000000000 Smkr 137 Food 122 Set 250 Probe3 270 00000000000000000000 00000000000000000000 Total Runtime 0 03 Power Output 100 Figure 14 Time...

Страница 12: ...ease check section 4 1 3 4 1 1 Multi Step Mode A total of 6 steps can be programmed on this controller Each program step comprises a target temperature of cabinet shown as SmkrTemp XXX and an ending c...

Страница 13: ...the AuberWIFI app to view and change both time and food temperature of each step for WIFI model only Cooking Profile Example Table 1 example program Step Number Cabinet Temp SmkrTemp X Ending Ending T...

Страница 14: ...ng the Time Back key to exit the menu Or you can use or key to go to Back and press SET key to exit The display can also return to the normal display mode if no key is pressed in about 15 seconds 0000...

Страница 15: ...d press the SET again to confirm the change That number will stop blinking Press the Timer Back key to exit the menu Or use or key to scroll to Back and then press SET key to exit The display will ret...

Страница 16: ...el Parameter is unchanged 00000000000000000000 00000000000000000000 Step 1 SmkrTemp 250 1 Ending by Fd Temp 00000000000000000000 00000000000000000000 Back Step 1 SmkrTemp 250 00000000000000000000 0000...

Страница 17: ...Config 7 1 Control Configurations Parameters related control configurations during the smoking process are listed under Control Config menu Error Reference source not found This shows the list of the...

Страница 18: ...display will flash between the normal display and the alarm display showing in Figure 22 The alarm has 1 degree hysteresis The user can mute the buzzer by pressing either the Up or Down key Temperatur...

Страница 19: ...129 F or lower To disable Food Hi Alarm you can set it to a large number such as 650 F When smoking multiple pieces of meat of different sizes put the probe in the thinnest piece first Set the Food H...

Страница 20: ...t is ON at Step 5 If F 0 smoke generator output is OFF at Step 6 If F 1 smoke generator output is ON at Step 6 Example To turn on the smoke generator output on step 2 and step 3 only this parameter ne...

Страница 21: ...is taking too long to eliminate the temperature offset When I 0 the system becomes a PD controller For very slow response systems such as slow cooker and large commercial rice cooker setting I 0 will...

Страница 22: ...ave this current program as a recipe for future use Go to the Parameter Setting mode by holding the SET key and then go to Control Setting menu find parameter Save Recipe and press the SET key again s...

Страница 23: ...escription Range Initial Note Program Mode Multi Step Program ON OFF ON 12 Output Hi Limit Output High Limit 0 100 100 13 Output Lo Limit Output Low Limit 0 100 0 13 Temp Unit Temp Unit C or F C F F 1...

Страница 24: ...ll output It thinks the 1000W heater as a 500W heater When the PID algorithm determines 50 output value the actual power output will be 250 watts This function can be used in two situations 1 When you...

Страница 25: ...ease check section 3 1 for details Note 17 P3 ALM TYPE Probe 3 alarm type options This parameter is for Probe3 Hi Alarm in Control Config menu Users can set this probe 3 alarm to be absolute high alar...

Страница 26: ...points The temperature plot of the AuberWIFI App has two scales One can display the latest 300 data points and other can display the latest 120 data points The default setting of Dwell time is 1 minut...

Страница 27: ...e placed away from direct sun light Users should also avoid exposing the controller to water and rain which could damage the controller b Low temperature control The control result for temperatures be...

Страница 28: ...e temperature manipulation For stable temperature control the controller requires two things 1 the controller must be set to the correct power level see next section and 2 that it must be tuned to the...

Страница 29: ...ontroller to the appropriate power level see next Section Turn the controller and cooker on and enter the desired set point temperature closed to your normal cooking temperature To activate auto tunin...

Страница 30: ...insulated cooker The auto tuning should be able to tune most of your chosen smokers with fairly good result Copyright 2021 Auber Instruments Inc All rights reserved No part of this manual shall be co...

Страница 31: ...or repairs services or alterations to the product or any of its parts that has been performed by a repairperson or facility not authorized by Auber Instruments This warranty is available to the origin...

Страница 32: ...When 15 Amp is passing through the controller 20 watts of heat are produced in the controller As more heat is produced the temperature inside the controller will rise If it reaches to higher than 70 C...

Страница 33: ...e 25 longer time to heat up the pot but the controller will not over heat In addition to these solutions the following information will also help you to manage the heat Place the controller in right p...