Au Group Electronics
Au SAE J1939 Simulator (Gen II) 2.00A User Manual Rev. D
26
Table 5-3
Controlled Steps vs. "EPS lamps" ON status
Engine Protection System (EPS)
Control Step Values
EPS Timer ON
4, 5, 6, 7, 100%
EPS EN
0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 100%
EPS Timer Override
9, 10, 100%
EPS Shutdown Engine
2, 3, 100%
EPS Approaching Shutdown
4, 5, 100%
Table 5-4
Controlled Steps vs. Warning lamps, message, specific SPN, and FMI
Control Step
value
Warning Lamps
Warning message
SPN
FMI
0% Engine Amber
Low engine coolant level
111
1
1 - 9% Engine Amber
Low battery electrical potential
168
1
10 - 19% Engine (Amber + Red Stop)
Low battery electrical potential
168
1
20% Engine (Amber + WIF)
Water in Fuel
97
15
21 - 29% Engine Amber
Low engine oil pressure
100
1
30 - 39% Engine (Amber + Red Stop)
Low engine oil pressure
100
1
40% Engine Amber
High battery electrical potential
168
0
41 - 49% Engine Amber
High engine coolant temperature
110
0
50 – 59% Engine (Amber + Red Stop)
High engine coolant temperature
110
0
60% Engine Amber
High engine oil pressure
100
0
61 - 69% ABS Amber
Brake switch short
597
1
70 – 80% ABS (Amber + Red Stop)
Brake switch short
597
1
81 - 89% Transmission Amber
Transmission oil temperature high
177
0
90 – 99% Transmission (Amber + Red Stop)
Transmission oil temperature high
177
0
100%
Engine (WIF +Red Stop + Amber)
+ ABS (Red Stop + Amber)
+Transmission (Red Stop + Amber)
Engine DM1, DM2 multi-packets,
ABS DM1 on,
Transmission DM1 on
Table 5-5
Controlled Steps vs. "Engine Basic Info lamps" ON status
Engine Information
Control Step Values
Wait to Start
0, 1, 2, 3, 4, 5, 100%
Overspeed Test
80, 100%
Air Shutoff
60, 100%
Alarm Output
20, 100%
Alarm Acknowledge
40, 100%
WIF 20,
100%
Engine Cruise Lamp Off
<40%
Engine Cruise Lamp On
>=40%
Table 5-6
Controlled Steps vs. "A/C & Refrigerant Switch" ON Status
A/C & Refrigerant Switch
Control Step Values
A/C High Pressure Fan Switch
20, 100%
Refrigerant Low Pressure Switch
40, 100%
Refrigerant High Pressure Switch
60, 100%
Au SAE J1939 Simulator Gen II 2.00A supported PGN, PGN description, and SPNs are listed in Table 5-7.