Au Group Electronics
Au SAE J1939 Simulator (Gen II) 2.00A User Manual Rev. D
10
o
Menu button is used to control Warning LED on/off. A single press on Menu button will turn on the Warning
LED if the Warning LED was off, and vice versa.
o
The Menu button function is available only on Engine Premium Edition(s) and Vehicle Platinum Edition(s). In
Engine Basic Edition(s), Menu button is not used, Warning LED is constantly off.
o
If buzzer is enabled, a short beep will be heard upon a press on the Menu button.
In dynamic mode, the simulator automatically adjusts the control step value by itself. This will generate dynamic J1939
signals. In static mode, all* simulated SAE J1939 signal will be controlled by the control step value, which is still able to
be manually controlled by the
Up
and
Down
buttons.
Note
: * The Engine Clock is not controlled by the control step value and push buttons; it runs all by itself just like a real
clock.
•
Press
Down
button:
o
Down
button is used to decrease the values of all J1939 signals. A single press will decrease all data one
step from previous values until they reach the minimum values.
▼
0% LED will be triggered on or off.
o
If
▼
0% LED is on, press
Down
button one time,
▼
0% LED will be off.
o
If
▼
0% LED is off, press
Down
button one time,
▼
0% LED will be on.
o
80% LED blinks when control step value equals to 80%,
o
60% LED blinks when control step value equals to 60%,
o
40% LED blinks when control step value equals to 40%,
o
20% LED blinks when control step value equals to 20%,
o
▼
0% LED blinks when control step equals to 0%,
o
If buzzer is enabled, a short beep will be heard upon a press on Down button.
•
Press
Up
button:
o
Up
button is used to increase the values of all J1939 signals. A single press will increase all simulated data
one step to next data level until they reach the maximum values,
▲
100% LED will be triggered on or off.
o
If
▲
100% LED is on, press
Up
button one time,
▲
100% LED will be off.
o
If
▲
100% LED is off, press
Up
button one time,
▲
100% LED will be on.
o
20% LED blinks when control step value equals to 20%,
o
40% LED blinks when control step value equals to 40%,
o
60% LED blinks when control step value equals to 60%,
o
80% LED blinks when control step value equals to 80%,
o
▲
100% LED blinks when control step value equals to the highest value, 100%.
o
If buzzer is enabled, a short beep will be heard upon a press on
Up
button.
•
Press and hold both
Down + Up
button for more than 1 second:
o
Down + Up buttons are used to turn buzzer on/off.
o
If buzzer is on, press and hold
Down + Up
for more than 1 second will silent buzzer thereafter.
o
If buzzer is mute, press and hold
Down + Up
for more than 1 second will enable the buzzer thereafter.
o
Both
▲
100% and
▼
0% LED will flip their on/off status as a visual indication of this dual-button input.
o
If buzzer is enabled, a long beep will be heard to reflect the input of
Down + Up
button.
•
Press and hold both
Menu + Down
button for more than 1 second:
o
Menu + Down
buttons are used to turn Engine DM2 warning on/Reset.
o
Both
▲
100% LED and
▼
0% LED will flip their status as a visual indication of this dual-button input.
o
If buzzer is enabled, a long beep will be heard to reflect the input of
Menu + Down
button.
o
The Engine DM2 warning messages (available only at premium editions and platinum editions) are always
on after power-on. It can be reset when an Engine DM3 PGN is received.
o
For continuous test purpose, after an Engine DM3 PGN is received, either re-power-on the simulator or
press and hold both
Menu + Down
button for more than 1 second will turn on the Engine DM2 warning
again.