CHAPTER 2: GENERAL (GLOBAL) CONFIGURATION
2-10
VersAtive
®
Pro, DigiVu
®
II, DigiVu
®
II Micro – Operation Manual
Trap Name
Description
versativeRolloverTrap
"This trap appears when PTS of elementary streams overlaps. "
versativePtsDiscontinuityTrap
"This trap appears when the program time stamp is changed. this can happen when the
transport stream changes. "
versativeCantRecordAudioFastEnoughTrap
"This trap appears when the VersAtive can't record audio fast enough. "
versativeFailToStartRtmpServerTrap
"This trap appears when the VersAtive fails to connect to the RTMP server. "
versativeOvfFifoSizeTrap
"This event appears when the SPTS MUX gets overflowed. "
versativeAc3AudioChangedTrap
"This trap appears when the AC3 audio changes. "
versativeDelayCalculationTrap
"This trap appears when the multiplexer loses sync. "
versativeAliveAfterEosTrap
"This trap appears when file transcoding is almost complete - Offline. "
versativeNoInputDataTrap
"This trap appears when no input data for the resource is detected. "
versativeExternalStopSignalReceivedTrap
"This trap appears when User initiates 'stop resource'. "
versativeEvntPsiMonitoringTrap
"This trap appears when there is a PSI change at the input. "
versativeEvntCcErrorTrap
"This trap appears when the resource has a continuity count error. "
versativeCapcardInputChangedTrap
"This trap appears when the capture card format changes. "
versativeMcEncValidationErrorTrap
This trap appears when there is an MPEG2 configuration error. This trap can only be an
Error.
versativeClosingConnectionsTrap
"This trap appears when the VersAtive closes all the streams. "
versativeFailedToPutFileTrap
This trap appears when an HLS or RTMP stream fails to publish.
versativeSignalDetectedTrap
"This trap appears when a signal for resource is detected. "
versativeReconnectTrap
"This trap appears when the VersAtive reconnects successfully to RTMP server. "
versativePipeEvntNoUdpInput
"This trap appears when there is no UPD input for the pipeline. "
VersAtive Hardware Traps
versativeMonitorCpuHeatTrap
"This trap appears when the CPU heat nears it's maximum operation temperature. This
trap can be an error or info. - Info message indicates that the CPU heat is at 70C degrees.
- Error message indicates that the CPU heat is at 75C degrees. "
versativeMonitorCpuLoadTrap
"This trap appear when the CPU usage nears it's maximum capacity. This trap can be
an error or info. - Info message indicates that the CPU usage is at 75 percent. - Error
message indicates that the CPU usage is at 85 percent. "
versativeMonitorMemoryUsageTrap
"This trap appears when the memory usage nears it's maximum capacity. This trap can
be an error or info. - Info message indicates that the memory usage is at 85 percent. -
Error message indicates that the memory usage is at 92 percent. "
versativeMonitorEthLimitTrap
"This trap appears when the Ethernet card nears it's maximum capacity. This trap can
be an error or info. - Info message indicates that the Ethernet card is at 80 percent of it's
capacity. - Error message indicates that the Ethernet card is at 90 percent of it's capacity. "
versativeMonitorDemodStatusTrap
This trap shows the status of the demod card (enabled/disabled or locked/not locked).
This trap can be an error or info. - Error message indicates that the demod card is not
locked. - Info message indicates that the demod card is locked, enabled or disabled.