Atwood hydro flame 7900-II series Скачать руководство пользователя страница 3

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

Listed  below  are  several  safety  related  items  that  you  the  (owner) 
should follow each heating season to assure continued safe operation 
of  the  furnace.  A  periodic  inspection  of  the  furnace  by  a  qualified 
service agent is also recommended. 
 

 

Inspect furnace venting. Venting must be free of obstructions, 
void of soot and properly terminated to the atmosphere. Make 
sure that the vent assembly is positioned tight against out door 
screens on 8500 and 8900 series. 

 

Periodically inspect the vent for obstructions or presence of soot. 
Soot is formed whenever combustion is incomplete. This is your 
visual warning that the furnace is operating in an unsafe manner. 
If soot is present, immediately shut furnace down and contact 
your dealer or a qualified service person. 

 

Keep furnace clean. More frequent cleaning may be required due 
to excessive lint from carpeting, bedding material, pet hair etc. It 
is imperative that control compartments, burners and circulating 
air passageways of the appliance be kept clean and 
unobstructed. 

 

The motor is permanently lubricated and requires no oiling. 

 

Keep the furnace area clear of any combustible materials, 
gasoline, or other flammable vapor and liquids. 

 

Before operating furnace, check the location of the furnace vent to 
make sure it will not be blocked by the opening of any door on the 
trailer. If it can be blocked, do not operate the furnace with the 
door open. 

 

Do not restrict the flow of combustion air or the warm air 
circulation to the furnace. To do so could cause personal injury 
and/or death. 

 

Never operate the furnace if you smell gas. Do not assume that 
the smell of gas in your RV is normal. Any time you detect the 
odor of gas, it is to be considered life threatening and corrected 
immediately. Extinguish any open flames including cigarettes and 
evacuate all persons from the vehicle. Shut off gas supply at LP 
gas bottle. (See safety notice in this manual). 

 

Immediately shut furnace down and call a service agency if 
furnace cycles erratically or delays on ignition. 

 

Never attempt to repair the furnace yourself. Seek the help of a 
qualified service person. 

 

Never restrict the ducting installed by your trailer manufacturer. 
To do so could cause improper furnace operation. 

 

Do not install air boosters in the duct system. Such devices will 
cause the furnace to cycle on limit and to have erratic sail switch 
operation. 

 

Clothing or other flammable material should not be placed on or 
near the appliance. 

 

Always follow the Operating Instructions. Do not deviate from the 
step-by-step procedures. 

 

When considering add-on rooms, porch or patio, attention must 
be given to the venting of our furnace. For your safety, do not 
terminate furnace vent inside add-on rooms, screen porch or onto 
patios. Doing so will result in products of combustion being vented 
into the room or occupied areas. 

 

In any installation in which the vent of the appliance can be 
covered due to the construction of the RV or some special feature 
of the RV such as slide out, pop-up etc. Always insure that the 
appliance cannot be operated by setting the thermostat to the 
positive “OFF” position and shutting off all electrical and gas 
supply to the appliance. Never operate furnace with vent covered. 

 

MAINTENANCE AND CLEANING 
 

 

 

 

 

 

 
 
 
 

 

 
 
 

 

 
 
 

 

SERVICING 

 CAUTION 

PERSONAL INJURY 

 

All sheet metal edges are sharp care should be taken when 
handling or brushing up against them to avoid cuts. 

 WARNING 

FIRE OR EXPLOSION 

 

 

Improper installation, adjustment, alteration, service or 
maintenance can cause property damage, personal 
injury or loss of life. Refer to the installation instructions 
and/or owners manual provided with this appliance. 

 

Installations, repairs and preventive maintenance 
should be done by a qualified Service Technician only. 

 

 WARNING 

FIRE OR EXPLOSION 

 

 

DO  NOT  refuel  gasoline  tanks  or  LP  tanks  unless  the 
gas  has  been  turned  OFF  at  the  LP  tank  disabling  all 
gas appliances and pilot lights. 

 

DO NOT over fill LP gas tanks. 

 

LP tanks must be filled by a qualified gas supplier only. 
Follow tank manufacture’s operating instructions located 
on tank.  

 

Liquid  gas  from  an  over  filled  tank  can  be  forced 
through the pressure regulator resulting in high pressure 
gas escaping, causing fire/explosions.  

  

WARNING 

POSSIBLE INJURY OR DEATH 

 

Do  not  use  this  appliance  if  any  part  has  been  under  water.  A 
flood-damaged  furnace  is  extremely  dangerous.  Attempts  to  use 
the furnace can result in fire or explosion.  
A  qualified  service  agency  should  be  contacted  to  inspect  the 
furnace  and  to  replace  all  gas  controls,  control  system  parts, 
electrical  parts  that  have  been  wet  or  the  furnace  if  deemed 
necessary.

 

  

WARNING 

POSSIBLE INJURY OR DEATH 

 

Should the gas supply fail to shut off or if overheating occurs, shut 

off  the  gas  valve  to  the  furnace  before  shutting  off  the  electrical 
supply.”

 

  

WARNING 

POSSIBLE INJURY OR DEATH 

 

Do  not  install  screens  over  the  vent  for  any  reason.  Screens  will 
become  restricted  and  cause  unsafe  furnace  operation. 
Accessories are being marketed for RV products which we do not 
recommend.  For  your  safety,  only  factory  authorized  parts  are  to 
be used on your furnace. 

  

WARNING 

FIRE OR EXPLOSION 

 

 

DO NOT alter the furnace to a positive grounding system. 

 

DO  NOT  use  battery  charger  to  supply  power  to  DC  model 
furnaces even when testing. 

 

DO NOT connect 120 VAC to 12 VDC furnaces. 

  

WARNING 

POSSIBLE INJURY OR DEATH 

 

If  the  user  of  this  appliance  fails  to  maintain  it  in  the  condition  in 
which  it  was  shipped  from  the  factory  or  if  the  appliance  is  not 
used  solely  for  its  intended  purpose  or  if  appliance  is  not 
maintained in accordance with the instructions in this manual, then 
the risk of a fire and/or the production of carbon monoxide exists 
which can cause personal injury, property damage or loss of life. 

Содержание hydro flame 7900-II series

Страница 1: ...ation service or maintenance can cause property damage personal injury or loss of life Refer to the installation instructions and or owners manual provided with this appliance CAUTION PERSONAL INJURY DO NOT touch exterior exhaust grills when furnace is operating Supervise young children in the same room as the furnace WARNING POSSIBLE INJURY OR DEATH Your furnace should be inspected by a qualified...

Страница 2: ...r use gasoline or other flammable vapors and or liquids in the vicinity of this or any other appliance DO NOT use the furnace cabinet area as a storage compartment DO NOT block furnace outlet registers or return air grills Keep all insulating material away from furnaces HOW TO TURN OFF ELECTRICAL POWER 1 Set the thermostat at the lowest setting 2 Open furnace exterior door and turn OFF electrical ...

Страница 3: ... products of combustion being vented into the room or occupied areas In any installation in which the vent of the appliance can be covered due to the construction of the RV or some special feature of the RV such as slide out pop up etc Always insure that the appliance cannot be operated by setting the thermostat to the positive OFF position and shutting off all electrical and gas supply to the app...

Страница 4: ...upstream of gas connections for checking gas pressure GAS TYPE BTU HR LINE PRESSURE REG PLUG SETTING DRILL SIZE Propane LP 40 000 11 WC 10 5 WC 49P Natural Nat 40 000 7 WC 3 5 WC 30N Propane LP 35 000 11 WC 10 5 WC 51P Natural Nat 35 000 7 WC 3 5 WC 32N WC Water Column VALVE CONVERSION 1 See drawing to check exposed section on side of adjustment reg plug to determine whether it is set for natural ...

Страница 5: ...he discretion of the manufacturer This warranty is void if the product has been damaged by accident unreasonable use neglect tampering or other cause not arising from defects in material workmanship This warranty extends to the original owner of the product only and is subject to the following conditions 1 For two years from the date of purchase Atwood will repair or replace any part defective in ...

Страница 6: ...or warranty service rendered on a direct basis only 4 Repairs replacement parts and or furnace replacement authorized by Atwood shall be subject to the remainder of the warranty of any of the aforesaid two year period EXCLUSIONS SPECIFICALLY EXCLUDED FROM THE WARRANTIES 1 Incidental or consequential damages 2 Damage caused by shipment 3 Damage resulting from improper installation misuse neglect ac...

Страница 7: ...7 EXTENDED SERVICE ORDER FORM ...

Страница 8: ...THIS PAGE INTENTIONALLY LEFT BLANK CETTE PAGE EST INTENTIONNELLEMENT VIDE ...

Страница 9: ...THIS PAGE INTENTIONALLY LEFT BLANK CETTE PAGE EST INTENTIONNELLEMENT VIDE ...

Страница 10: ...THIS PAGE INTENTIONALLY LEFT BLANK CETTE PAGE EST INTENTIONNELLEMENT VIDE ...

Страница 11: ... service qualifié pour inspecter l appareil et remplacer toute pièce du système de commande et toute commande de gaz qui a été en contact avec de l eau AVERTISSEMENT INCENDIE OU EXPLOSION Assurez vous que la fournaise et tous les systèmes d allumage sont sur OFF ARRÊT durant tout processus de ravitaillement en carburant et pendant que le véhicule est en mouvement ou est remorqué AVERTISSEMENT BLES...

Страница 12: ...PAS ou n utilisez pas de l essence ou tout autre liquide ou vapeur inflammable à proximité de cette fournaise ou tout autre appareil N UTILISEZ PAS la zone de l armoire de la fournaise comme compartiment d entreposage NE BLOQUEZ PAS les registres de sortie de la fournaise ou les grilles d air repris Gardez tout le matériel d isolation loin des fournaises COMMENT COUPER LE COURANT ÉLECTRIQUE 1 Régl...

Страница 13: ... attention à la ventilation de votre fournaise Pour votre sécurité ne raccordez pas l évent de la fournaise à l intérieur de pièces ajoutées du grillage de la véranda ou sur les terrasses Ceci entraînerait la ventilation des produits de combustion à l intérieur de la pièce ou les aires habitables Dans toute installation dans laquelle l évent de l appareil peut être couvert en raison de la construc...

Страница 14: ...f frein filet sur les fils d orifice lors de l installation d un nouvel orifice Une prise NPT de 1 8 est fournie en amont des connexions de gaz pour vérifier la pression de gaz TYPE DE GAZ BTU HR PRESSION DE LIGNE RÉGLAGE DU BOUCHON REG GRANDEUR DE FORET Propane LP 40 000 11 WC 10 5 CE 49P Naturel Nat 40 000 7 WC 3 5 CE 30N Propane LP 35 000 11 WC 10 5 CE 51P Naturel Nat 35 000 7 WC 3 5 CE 32N CE ...

Страница 15: ... ou usées GARANTIE Atwood Mobile Products GARANTIE LIMITÉE DE LA FOURNAISE hydro flammeMC Atwood Mobile Products garantit au propriétaire original et sous réserve des conditions mentionnées ci dessous que le produit hydro flammeMC sera exempt de défauts de fabrication et de matériau pendant une période de deux ans suivant la date d achat originale La responsabilité d Atwood en vertu de la présente...

Страница 16: ...rvice de garantie rendu sur une base directe seulement 4 Les réparations les pièces de rechange et ou le remplacement de la fournaise autorisé par Atwood seront assujettis à la période restante de la garantie de toute période de deux ans susvisée EXCLUSIONS SONT SPÉCIFIQUEMENT EXCLUS DES GARANTIES 1 Les dommages indirects ou consécutifs 2 Les dommages causés par une expédition 3 Les dommages surve...