13
WIRING
Before routing the wires, disconnect the 12 VDC power supply to avoid
shorting. Make sure that the power connections are made to a properly
fused circuit (15 amp maximum) 1 amp fuse is recommended for single or
multiple detector installation. Can be fused through a distribution panel or
power supply box.
Connection to a
Master Storage Switch
is acceptable. The alarm will
be off along with all other 12 volt equipment when the storage switch
is turned to the off position.
DO NOT USE THE RV WHEN THE
STORAGE SWITCH IS IN THE OFF POSITION.
All connections must be in accordance with the National Electrical
Code in the United States and the Canadian Electric Code in Canada.
All connections must use approved wiring and connectors of an
appropriate size see wiring diagram label. Provide a minimum of 8
square inches to make wiring connection for DC models.
Some models are hard wired with a 110 AC adapter allowing the unit to be
plugged directly into a 110 AC wall outlet.