background image

 

READ ENTIRE MANUAL BEFORE USING THIS ALARM 

Your new Atwood Propane (LP) alarm is a sophisticated instrument that 
has been carefully designed and tested to detect LP build up in a 
residential or recreation vehicle environment. 
Liquefied Petroleum (LP or Propane) gas can cause hazardous conditions 
when found in high concentrations. Gas is known to be found in 
recreational vehicles and the proper detection of this gas provides a safe 
environment for the occupants of the vehicle. 
 

THIS ALARM HAS A SEVEN YEAR LIFE, SEE END OF LIFE 

NOTIFICATION 

 

Liquefied Petroleum Gas Awareness 

LP gas is commonly called Propane and is sold commercially as a suitable 
fuel in portable and permanent heating and cooking appliances. 
It is important to detect LP gas due to its explosiveness at concentrated 
volumes. This detector is design to alarm at <25% LEL (legal explosive 
limit). 

 

SAFETY ALERT SYMBOLS 

Safety symbols alerting you to potential personal safety hazards, 
Obey all safety messages following these symbols. 

 

 

WARNING

 

Avoid possible injury or death 

 

CAUTION

 

Avoid possible injury and/or property 

damage 

 

Содержание 31005

Страница 1: ...TRUCTIONS TESTED TO UL1484 For questions concerning your Alarm please call our Customer Service at 1 866 869 3118 Please have the following information ready when calling Alarm Model Number located on...

Страница 2: ...Power Off Mode 8 Normal Stand by Mode 8 Alarm Mode 9 Test Mode 9 Silence Stabilization Mode 9 Fault Mode 9 FUNCTIONS 10 INSTALLATION INSTRUCTIONS 11 WIRING 13 FLUSH MOUNTING 14 SURFACE MOUNTING 15 AC...

Страница 3: ...nt for the occupants of the vehicle THIS ALARM HAS A SEVEN YEAR LIFE SEE END OF LIFE NOTIFICATION Liquefied Petroleum Gas Awareness LP gas is commonly called Propane and is sold commercially as a suit...

Страница 4: ...been aired out and your alarm returns to its normal condition 2 Call your local Emergency Services Number or 911 Fill in your local Fire Department number here 3 After following steps 1 2 if your alar...

Страница 5: ...cates propane is presence WARNING Test Alarm operation after vehicle has been in storage before each trip and at least once per week during use WARNING Activation of this device indicates the presence...

Страница 6: ...operation Executing the test function sounds the alarm and lights up the LED The test will sound the alarm twice with 4 beeps in 1 second followed by 5 seconds of silence By pressing the button you ca...

Страница 7: ...ack LP_ARB 31006 Black Surface Bracket 35146 Black Surface Bracket 35147 White Adapter Plate 35180 Black Adapter Plate 35181 White SPECIFICATIONS Gas Detection LP Alarm Level 25 of the LEL of propane...

Страница 8: ...on provide interaction and feedback with your alarm and allow you to troubleshoot your alarm and to determine the proper actions to take The alarm operates in seven separate modes that will be identif...

Страница 9: ...de This mode will be exited automatically within 10 seconds Silence Stabilization Mode This mode indicates that the alarm is stabilizing for the first 3 minutes after power up or after the Reset Funct...

Страница 10: ...eactivated The LED will be flashing Yellow The audible alarm will chirp every 30 seconds Note two self adhesive emergency contact labels are provided The user must add telephone numbers for the local...

Страница 11: ...as possible to appliances that could be potential sources of LP gas leaks and where the initial concentration may be greatest Do not install directly in front of air or furnace vents DO NOT INSTALL n...

Страница 12: ...y damage or temporarily contaminate the sensor Avoid spraying air freshener hair spray paint or other aerosols near the alarm The following is a list of substances that at high levels can affect the s...

Страница 13: ...ong with all other 12 volt equipment when the storage switch is turned to the off position DO NOT USE THE RV WHEN THE STORAGE SWITCH IS IN THE OFF POSITION All connections must be in accordance with t...

Страница 14: ...inside the bracket and snap in place see diagram To remove flush mounting bracket pull legs away from body of detector 1 Verify that there is a minimum of C 1 1 2 inches of free space behind the wall...

Страница 15: ...g and connect wires to the detector per the wiring diagrams 3 Center and mount the base over the outline done in step 1 with the two screws provided through the two holes in the mounting base 4 Slip t...

Страница 16: ...2 The detector will sound twice 3 The LED will turn red and then return to normal operation and turn green after 8 seconds 4 This test must be carried out not less than once per week to ensure proper...

Страница 17: ...ons to reduce to battery draw down Power Failure If no power is applied to the unit or there is a failure of power circuits there will be no identification from the LED If there is no indication from...

Страница 18: ...eunder is limited to the replacement of the product repair of the product or replacement of the product with a reconditioned product at the discretion of the manufacturer This warranty is void if the...

Страница 19: ...the original warranty period 6 Damage or failure resulting from misuse including failure to seek proper repair service Misapplication alternations water damage freezing or not using genuine Atwood pa...

Страница 20: ...part at no charge and reasonable labor charges to replace it This Gas Detector is designed for use in recreation vehicles for warning of LP gas Any other use unless authorized in writing by the Atwoo...