11
IMPORTANT
– If this alarm does not test properly return it
immediately for repair or replacement.
A flashing LED blinks once every second
An audible alarm in
“fault state” chirps once every 30 seconds
An audible alarm in “alarm state” chirps 4 times every 5
seconds
CAUTION
Installation should be performed by a qualified technician
INSTALLATION INSTRUCTIONS
LP units when possible should be mounted to detect LP gas closer to
the floor due to its heavier than air nature.
Select a location as close as possible to appliances that could be
potential sources of LP gas leaks and where the initial concentration
may be greatest. Do not install directly in front of air or furnace vents.
DO NOT INSTALL
next to doors or windows that may dilute the
concentration of any LP gas presents in the environment and
preclude a timely alarm signal.
DO NOT INSTALL
the detector in a closet or in a location that could
become obstructed by a curtain, hanging clothes or any other objects.
DO NOT LOCATE
detector where it could be exposed to splashes of
water or grease or where it could be damaged by impact with moving
objects (i.e. furniture, feet, etc.).
DO NOT INSTALL
on a wall switch controlled by a power line or