36
Option
Submenu
Indication
Information
Test of device
O
2
scales
End of the test (+, –)
After pressing the „+“ button is the text „calibrate“
displayed
The calibration takes approx. 600 seconds.
Automatic calibration is done only in the case that
the boiler did not burn for 48 hours and the
operating time of the sensor is higher than 200
hours. By the manual setting there must be no fire
in the boiler, nor the glowing rest of the fuel! If it is
not necessary to adjust the scale, press „
←
“ and
the next step is displayed.
Note: For quick exit from menu press „+“ and „–“ at
once.
Flue gas fan
End of the test (+,–)
By pr start the flue gas fan
By pressing – stop the flue gas fan
By pressing
←
select the next point of the test
Circuit pump
End of the test (+,–)
By pr start the circuit pump
By pressing – stop the circuit pump
By pressing
←
select the next point of the test
Primary motor
End of the test (+,–)
By pr open the primary air flap
By pressing – close the primary air flap
By pressing
←
select the next point of the test
Secondary motor
End of the test (+,–)
By pr open the secondary air flap
By pressing – close the secondary air flap
By pressing
←
select the next point of the test
Illumination
End of the test (+,–)
By pr turn the text display illumination on
By pressing – turn the text display illumination off
By pressing
←
select the next point of the test
Indicator light 1
End of the test (+,–)
By pr turn the indicator light 1 on
By pressing – turn the indicator light 1 off
By pressing
←
select the next point of the test
Indicator light 2
End of the test (+,–)
By pr turn the indicator light 2 on
By pressing – turn the indicator light 2 off
By pressing
←
select the next point of the test
Indicator light 3
End of the test (+,–)
By pr turn the indicator light 3 on
By pressing – turn the indicator light 3 off
By pressing
←
select the next point of the test
Safety test
Setting
END