7. Test Descriptions
7.4.3
Optional Tests
GRN/GRN, GRN/YEL, YEL/GRN, YEL/YEL, Permissive (Non-Programmed Card)
Test Description :
Run this test with a "clean" (non-programmed) card to verify that there are no hidden permissives.
Test Sequence :
1. Monitor is powered up in the quiescent state.
2. Conflicting GRN or YEL signals are presented to each channel pair.
Note :
This test should be done with a "clean" programming card in the monitor (no permissives programmed)
Monitor Response to PASS
:
Each channel pair must put monitor into fault state when the conflict is presented.
RED/GRN/YEL Single Channel
Test Description :
Line voltage is applied to each RED, GRN, and YEL input one at a time to verify that a single input will not cause the
monitor to go into the fault state.
Test Sequence :
1. Monitor is powered up in the quiescent state.
2. AC line voltage is applied to RED1 for 750ms.
3. AC line voltage is applied to GRN1 for 750ms.
4. AC line voltage is applied to YEL1 for 3600ms.
5. AC line voltage is applied to RED1.
6. Repeat 2 through 5 for each channel.
Monitor Response to PASS
:
Monitor must NOT be found in fault.
GRN/YEL Single Channel
Test Description :
Line voltage is applied to each, GRN, and YEL input one at a time to verify that a single input will not cause the
monitor to go into the fault state.
Test Sequence :
1. Monitor is powered up in the quiescent state.
2. AC line voltage is applied to GRN1 for 750ms.
3. AC line voltage is applied to YEL1 for 3600ms.
4. Repeat 2 through 3 for each channel.
Monitor Response to PASS
:
Monitor must NOT be found in fault.
Short YEL
Test Description :
Apply the GRN, YEL, RED sequence to each channel with a 2 second YEL to verify that the monitor will go into the
fault state.
Test Sequence :
1. Monitor is powered up in the quiescent state.
2. AC line voltage is applied to GRN1 for 2 sec.
3. AC line voltage is applied to YEL1 for 2 sec.
4. AC line voltage is applied to RED1.
PCMT-8000 User's Manual
Rev. 1.7
61 of 80