7. Test Descriptions
1. Monitor is powered up in the quiescent state.
2. Redenable input is activated.
3. A negative rectified sine wave greater than 70Vrms is applied to each RED channel.
Monitor Response to PASS
:
Monitor must NOT be found in fault state.
RED 50Vrms Sine Wave Recognition
Test Description :
Verify that a sign wave less than 50Vrms is recognized as being "off" for every RED channel input.
Test Sequence :
1. Monitor is powered up in the quiescent state.
2. All RED channels are at AC line voltage.
3. Redenable input is activated.
4. A sine wave less than 50Vrms is applied to each RED channel one at a time.
5. fault state is checked for each channel.
Monitor Response to PASS
:
50Vrms on any RED channel must cause monitor to go into fault state (Redfail fault).
RED 50Vrms Positive Rectified Recognition
Test Description :
Verify that a positive rectified sign wave less than 50Vrms is recognized as being "off" for every RED channel input.
Test Sequence :
1. Monitor is powered up in the quiescent state.
2. All RED channels are at AC line voltage.
3. Redenable input is activated.
4. A positive rectified sine wave less than 50Vrms is applied to each RED channel one at a time.
5. fault state is checked for each channel.
Monitor Response to PASS
:
50Vrms on any RED channel must cause monitor to go into fault state (Redfail fault).
RED 50Vrms Negative Rectified Recognition
Test Description :
Verify that a negative rectified sign wave less than 50Vrms is recognized as being "off" for every RED channel input.
Test Sequence :
1. Monitor is powered up in the quiescent state.
2. All RED channels are at AC line voltage.
3. Redenable input is activated.
4. A negative rectified sine wave less than 50Vrms is applied to each RED channel one at a time.
5. fault state is checked for each channel.
Monitor Response to PASS
:
50Vrms on any RED channel must cause monitor to go into fault state (Redfail fault).
GRN, YEL, WLK 25Vrms Recognition (Sine Wave, Positive Rectified, Negative Rectified)
Test Description :
Verify that the monitor recognizes a signal greater than 25Vrms as being "on" for every GYW channel.
Test Sequence :
1. Monitor is powered up in the quiescent state.
PCMT-8000 User's Manual
Rev. 1.7
30 of 80