![Atop SW5501 Скачать руководство пользователя страница 100](http://html1.mh-extra.com/html/atop/sw5501/sw5501_user-manual_3004804100.webp)
SW5501 – SW5502
Wireless Serial Server
User Manual
VCOM installation
and troubleshooting
rate that is in effect for the virtual COM port
.
Include Domain in Windows Credentials
:
If credential option is set to Windows Credentials
(
See option in
Paragraph 6.2.3 above
and this option is enabled, VCOM automatically adds the current Windows domain to
the username
.
COM Port Control Keep
-
Alive
:
This option
controls the interval at which VCOM will issue the keep
-
alive
message
.
If the value is set to zero,
there will be no activity or no keep
-
alive packet sending out
.
The default
value is 60000 milliseconds
.
Maximum Connection Recovery Interval
:
This option controls the maximum time for restoration of
failed
connection
.
The default value is 30000 milliseconds
.
Enable SETXON
/
SETXOFF COM Port Commands
:
This option enables additional negotiation on SETXON and
SETXOFF commands and is only available for the
“
V
”
series serial device servers
.
If the application requires
SETXON
/
SETXOFF feature, please contact Atop Technical Support
.
6.5.2
Using Serial/IP with a Proxy Server
The Serial
/
IP Redirector also supports TCP network connections made through a proxy server, which may be
controlling access to external networks
(
such as the Internet
)
from a private network that lacks transparent IP
-
based routing, such as Network Address Translation
(
NAT
).
You can enable Serial
/
IP support of Virtual COM port
through the proxy server using Serial
/
IP Proxy Server settings
.
You can find Proxy Server settings from the
Advanced Settings windows and click on the Proxy Server tab as shown below
.
To enable the use of proxy server,
check the box in front of Use a Proxy Server option
.
Then, select the Protocol Type which can be HTTPS or Socks
V4 or Socks V5 from a drop
-
down list
.
Then, enter the IP address of the proxy server in the text box under IP Address
of Server field and specify the Port Number
.
Note that the default port number for HTTPS is 8080, while for Socks
V4 and V5 is 1080
.
Optionally, you can enter the Username and Password which may be required by your proxy
server in the Login to Server Using box
.
Alternately, you can click on the Auto Detect button to have the software
automatically detect the proxy server settings for you
.
Finally, you can test the proxy server settings by clicking on
the Test button and stop the testing by clicking on Stop button
.
Figure 6.19
Proxy Server Tab under Serial
/
IP Advanced Settings