![Atlas Copco ZR 110 Скачать руководство пользователя страница 287](http://html.mh-extra.com/html/atlas-copco/zr-110/zr-110_instruction-book_3001728287.webp)
Activities
Level A
Level B
Level C
Inspect and operate the dryer bypass valves (open/close
position)
X
X
X
9.2
Motor greasing
General
Stop the compressor and follow the LOTO procedure (Lock Out - Tag Out) (refer to
General Safety Precautions) before greasing.
Never mix greases of different brands or types.
Main motor bearings
Refer to the motor re-greasing data plate for the recommended grease type, the greasing quantity and
interval for the motor bearings.
Fan motor bearings of ZT compressors
The bearings of the fan motor are greased for life.
9.3
Oil specifications
Roto-Z lubricating oil
Use Atlas Copco Roto-Z oil which is specially developed for oil-free rotary compressors. This oil has a
long service life and ensures optimum lubrication.
Atlas Copco Roto-Z oil can be ordered in following quantities:
Quantity (l)
Quantity (US gal)
Quantity (Imp gal)
Quantity (cu.ft)
Ordering number
5 l can
1.32 US gal can
1.10 Imp gal can
0.18 cu.ft can
2908 8503 00
20 l can
5.28 US gal can
4.40 Imp gal can
0.70 cu.ft can
2908 8501 01
209 l drum
55.18 US gal drum
45.98 Imp gal drum
7.32 cu.ft drum
2908 8500 00
9.4
Storage after installation
Run the compressor, e.g. twice a week, until warm.
If the compressor is going to be stored without running from time to time, protective measures must be
taken. Consult Atlas Copco.
Instruction book
2920 1815 04
285
Содержание ZR 110
Страница 2: ......
Страница 177: ...Dimension drawing of ZR 110 up to ZR 145 Full Feature page 1 Instruction book 2920 1815 04 175 ...
Страница 178: ...Dimension drawing of ZR 110 up to ZR 145 Full Feature page 2 Instruction book 176 2920 1815 04 ...
Страница 179: ...Dimension drawing of ZT 110 up to ZT 145 page 1 Instruction book 2920 1815 04 177 ...
Страница 193: ...Drawings DIN to JIS adaptor flange with inner pipe diameter ranging from 32 to 65 mm Instruction book 2920 1815 04 191 ...
Страница 194: ...DIN to JIS adaptor flange with inner pipe diameter ranging from 80 to 125 mm Instruction book 192 2920 1815 04 ...
Страница 204: ...Installation proposal for ZT 110 up to ZT 145 and ZT 132 160 VSD Instruction book 202 2920 1815 04 ...
Страница 214: ... CORRECT installation Instruction book 212 2920 1815 04 ...
Страница 230: ...Electric connections for compressors with star delta starter Model year 2014 Instruction book 228 2920 1815 04 ...
Страница 231: ...Electric connections for compressors without a starter Model year 2003 Instruction book 2920 1815 04 229 ...
Страница 248: ...Start up Electric cabinet of compressor with starter Model year 2003 Instruction book 246 2920 1815 04 ...
Страница 249: ...Electric cabinet of compressor with starter Model year 2014 Instruction book 2920 1815 04 247 ...
Страница 250: ...Electric cabinet of compressor without starter Model year 2003 Instruction book 248 2920 1815 04 ...
Страница 257: ...Regulation valves for ZR Full Feature compressors without dryer by pass Instruction book 2920 1815 04 255 ...
Страница 258: ...Regulation valves for ZR Full Feature compressors with dryer by pass Instruction book 256 2920 1815 04 ...
Страница 259: ...Regulation valves for ZR Full Feature compressors without dryer by pass Instruction book 2920 1815 04 257 ...
Страница 260: ...Regulation valves for ZR Full Feature compressors with dryer by pass Instruction book 258 2920 1815 04 ...
Страница 261: ...Regulation valves for ZT Full Feature compressors without dryer by pass Instruction book 2920 1815 04 259 ...
Страница 266: ...Drain connections on ZR 160 Full Feature up to ZR 275 Full Feature Instruction book 264 2920 1815 04 ...
Страница 269: ...Control panel Control panel of Elektronikon GraphicPlus controller Instruction book 2920 1815 04 267 ...
Страница 289: ...10 2 Oil and oil filter change Oil system Oil system components ZR 110 up to ZR 275 Instruction book 2920 1815 04 287 ...
Страница 326: ......
Страница 327: ......