Compressor protection
Shutdown warning
A shutdown
warning
level is set less critical than the shutdown level.
The compressor is equipped with several sensors to check pressures and temperatures. If one of these
measurements exceeds the set shutdown warning level, a message will be displayed and the general alarm
LED (next to the exclamation mark) will be lit to warn the operator.
The warning message disappears as soon as the measurement is below warning level.
Shutdown
If one of the sensors reaches a set shutdown level, the compressor will be stopped. This will be displayed
on the controller and the general alarm LED will blink.
Solve the problem and reset the message. See also the
Before remedying, always check the applicable safety precautions.
Service warning
A number of service intervals are grouped into
Service Plans
, all with their own time frame. If a service
interval is reached, a message will appear on the controller display to warn the operator to carry out the
prescribed service actions stated in a certain Service Plan.
Automatic restart after voltage failure (ARAVF)
The controller allows automatic restart of the compressor unit if the supply is restored after voltage failure.
For compressors leaving the factory, this function is disabled. If desired, this function can be enabled by
your local Atlas Copco Customer Center.
Assuming the controller was running in automatic operation, the compressor unit will
restart when the supply voltage to the module is restored if ARAVF is enabled. As long
as the emergency stop is enabled, ARAVF is disabled.
Instruction book
2920 1815 04
113
Содержание ZR 110
Страница 2: ......
Страница 177: ...Dimension drawing of ZR 110 up to ZR 145 Full Feature page 1 Instruction book 2920 1815 04 175 ...
Страница 178: ...Dimension drawing of ZR 110 up to ZR 145 Full Feature page 2 Instruction book 176 2920 1815 04 ...
Страница 179: ...Dimension drawing of ZT 110 up to ZT 145 page 1 Instruction book 2920 1815 04 177 ...
Страница 193: ...Drawings DIN to JIS adaptor flange with inner pipe diameter ranging from 32 to 65 mm Instruction book 2920 1815 04 191 ...
Страница 194: ...DIN to JIS adaptor flange with inner pipe diameter ranging from 80 to 125 mm Instruction book 192 2920 1815 04 ...
Страница 204: ...Installation proposal for ZT 110 up to ZT 145 and ZT 132 160 VSD Instruction book 202 2920 1815 04 ...
Страница 214: ... CORRECT installation Instruction book 212 2920 1815 04 ...
Страница 230: ...Electric connections for compressors with star delta starter Model year 2014 Instruction book 228 2920 1815 04 ...
Страница 231: ...Electric connections for compressors without a starter Model year 2003 Instruction book 2920 1815 04 229 ...
Страница 248: ...Start up Electric cabinet of compressor with starter Model year 2003 Instruction book 246 2920 1815 04 ...
Страница 249: ...Electric cabinet of compressor with starter Model year 2014 Instruction book 2920 1815 04 247 ...
Страница 250: ...Electric cabinet of compressor without starter Model year 2003 Instruction book 248 2920 1815 04 ...
Страница 257: ...Regulation valves for ZR Full Feature compressors without dryer by pass Instruction book 2920 1815 04 255 ...
Страница 258: ...Regulation valves for ZR Full Feature compressors with dryer by pass Instruction book 256 2920 1815 04 ...
Страница 259: ...Regulation valves for ZR Full Feature compressors without dryer by pass Instruction book 2920 1815 04 257 ...
Страница 260: ...Regulation valves for ZR Full Feature compressors with dryer by pass Instruction book 258 2920 1815 04 ...
Страница 261: ...Regulation valves for ZT Full Feature compressors without dryer by pass Instruction book 2920 1815 04 259 ...
Страница 266: ...Drain connections on ZR 160 Full Feature up to ZR 275 Full Feature Instruction book 264 2920 1815 04 ...
Страница 269: ...Control panel Control panel of Elektronikon GraphicPlus controller Instruction book 2920 1815 04 267 ...
Страница 289: ...10 2 Oil and oil filter change Oil system Oil system components ZR 110 up to ZR 275 Instruction book 2920 1815 04 287 ...
Страница 326: ......
Страница 327: ......