8.8
Safety valves
Location of safety valve
Testing
The safety valve (SV) test can only be performed by authorized personnel and is
protected by a security code.
Refer to Elektronikon™ Touch controller.
If the safety valve does not open at the set pressure stamped on the valve, it needs to be
replaced.
Warning
No adjustments are allowed. Never run the compressor without safety valve.
8.9
Service intervals filters
UD+ filters
The filter elements of oil mist filters (UD+) should be replaced after 4000 hours. The gauge or
pop-up is not a measure, as a typical oil mist filter operates in the steady state mode during its
life and this mode is e.g. 200-250 mbar.
Note that the indicator or gauge will not move into the red area but will stay yellow or orange
during operation.
Summarizing, the following service intervals should be observed (whatever comes first):
• 4000 operating hours
• 12 months in use
• Pressure drop: 350 mbar