![Atlas Copco GA 11+ Скачать руководство пользователя страница 100](http://html.mh-extra.com/html/atlas-copco/ga-11/ga-11_instruction-book_3001656100.webp)
7
Operating instructions
7.1
Initial start-up
The operator must apply all applicable
.
For the location of the air outlet valve and the drain connections, see sections
Preparations
1. Consult the sections
.
2.
The following transport fixtures, painted red, must be removed:
• Bolt (1)
• Bolts and bushes under the gear casing (2)
• Support (3)
3. Check that the electrical connections correspond to the applicable codes and that all wires
are clamped tight to their terminals.
The installation must be earthed and protected against short circuits by fuses of the inert
type in all phases. An isolating switch must be installed near the compressor.
4. Check transformer (T1) for correct connection.
Check the settings of drive motor overload relay (F21).
Check that the motor overload relay is set for manual resetting.
Instruction book
98
2920 7118 31