Installation and Operation Manual
Document #9620-20-b-mc-16 base tool changer-07
Pinnacle Park
•
1031 Goodworth Drive
•
Apex, NC 27539
•
Tel: 919.772.0115
•
Fax: 919.772.8259
•
www.ati-ia.com
•
Email: [email protected]
B - 8
Push the quick action rod release button on the Master body. Be sure the Tool is engaged
with the Master. There should be no gap between the Master and Tool at this time.
Figure 3.2 —Push Button for Quick Locking
Then apply the tightening torque to the knob to provide the final clamping force. In lab
testing, 25 in-lbs of tightening torque was determined to provide the optimal clamping force,
but anywhere between 10 in-lbs and 25 in-lbs is adequate. This tightening force range equates
to the average human tightening a knob by hand. Do not use a tool and over-tighten or
excessive wear on components will occur and the product lifespan will be shortened.
Figure 3.3 —Tighten Knob for Full Lock
Tighten clockwise by
hand to provide the
lock force