Serial Console Server User Manual
72
Save & Copy
At the bottom right side of each Properties page you can click
Save
to save the
settings for the selected port, or
Save&Copy
which allows you to copy and save
the current port settings for any/all other ports, as shown here:
Simply select the ports you want to save the current setting to and click
OK
.
Port Name
You can give a port an appropriate name by editing the
Port Name
field.
Baud Rate
This sets the port’s data transfer speed. Choices are from 300
–
115200 (drop down the list to see all options). Set this to match the
baud rate setting of the connected device. Default is 9600 (which is a
default setting for many serial devices).
Data Bits
This sets the number of bits used to transmit one character of data.
Choices are: 5, 6, 7 and 8. Set this to match the data bit setting of the
connected device. Default is 8 (which is a default setting for many
serial devices).
Parity
This bit checks the integrity of the transmitted data. Choices are:
None; Odd; Even; Mark; Space. Set this to match the parity setting of
the connected device. Default is None (which is a default setting for
many serial devices).
Stop Bits
This indicates that a character has been transmitted. Set this to match
the stop bit setting of the connected device. Choices are: 1, 1.5, and
2. Default is 1 (which is a default setting for many serial devices).
Flow Control
This allows you to choose how the data flow will be controlled.
Choices are: None, Hardware (RTS/CTS), and XON/XOFF. Set this to
match the flow control setting of the connected device. Default is
None.
Toggle DTR
Enabling this parameter allows the DTR signal to toggle between
enabled and disabled. A check mark
(
√
)
enables Toggle DTR.
Online Detect
This allows you to set the DSR signal to detect the online status of
each port. If Online Detect is disabled, the
Status
column on the
Port
Access - Connections
page will always show as
None
for the port,
providing no indication of the port or device status.
Setting
Meaning
Содержание SN0108A
Страница 16: ...Serial Console Server User Manual xvi This Page Intentionally Left Blank ...
Страница 36: ...Serial Console Server User Manual 20 This Page Intentionally Left Blank ...
Страница 48: ...Serial Console Server User Manual 32 This Page Intentionally Left Blank ...
Страница 56: ...Serial Console Server User Manual 40 This Page Intentionally Left Blank ...
Страница 108: ...Serial Console Server User Manual 92 This Page Intentionally Left Blank ...
Страница 136: ...Serial Console Server User Manual 120 This Page Intentionally Left Blank ...
Страница 148: ...Serial Console Server User Manual 132 This Page Intentionally Left Blank ...