[21]
5.2.2.
Segmented Error Compansation Function:
If the scale makes errors in different dimensions this
function is used for compensation. It cam make compensation up to 100 point. Please select
segmented option from system setting menu.
Please move the scale to reference point and enter the points in definite distances.
To make active the function the device must be on ABS mode. The axis which will be correct must be selected and
press
button. Press Sx button and enter the segment number. Press enter again. Press
button for next
step. Press Sx button and enter the distance as mm and press enter again to save. Press
button for next step.
BIt is possible to pass this step as two selection. First selection is adjustment of scale zero. To adjust the scale zero
when there is writting “RULER ZERO” press enter. By moving the scale please provide to send zero signal to the
device. When the zero signal is received the system pass to second step automatically. Second selection is
adjustment of mechanical zero point. When there is writting “RULER ZERO” on the screen press “HOLD” button .
there will be writting “MACH. ZERO” on the info screen. Move the scale to left end and press enter to save.
After adjustment of scale zero point enter the first correction point. Move the table according to distance which
entered before. You will see the error value on the screen. Press Sy button and enter the correct value and press
ente to save. After saving the value you will see the error value on the screen again. Pass to 2. Point by
buttton
and make the same operations for the other points. Afetr finishing all points press
button to exis
Example:.
On Z axis the errors are determined with 50 mm distances. To compensate the error;
1
2
3
4
5
6
7
Error
0
Start Point
Distance
Affirmation Points
1. Point Read Value: 52.285 mm
2. Point Read Value: 98.750 mm
3. Point Read Value: 154.045 mm
Error
2
Distance
1
3
50mm
100mm
200mm