background image

ATD4P9DXL_rev_0318

SAVE THESE INSTRUCTIONS 

SAFETY INSTRUCTIONS 

When using your garage equipment, basic safety precautions should always be followed, including the 
following: 

  Read all instructions 
  Care must be taken as burns can occur from touching hot parts. 
  Do not operate equipment with a damaged cord or if the equipment has been dropped or damaged - 

until it has been examined by a qualified service person. 

  Do not let a cord hang over the edge of the table, bench, or counter or come in contact with hot 

manifolds or moving fan blades. 

  If an extension cord is necessary, a cord with a current rating equal to or more than that of the 

equipment should be used. Cords rated for less current than the equipment may overheat. 

  Always unplug equipment from electrical outlet when not in use.  Never use the cord to pull the plug 

from the outlet. Grasp plug and pull to disconnect.

  Let equipment cool completely before putting away. Loop cord loosely around equipment when storing. 
  To reduce the risk of fire, do not operate equipment in the vicinity of open containers of flammable 

liquids (gasoline). 

  Adequate ventilation should be provided when working on operating internal combustion engines. 
  Keep hair, loose clothing, fingers, and all parts of body away from moving parts. 
  To reduce the risk of electric shock, do not use on wet surfaces or expose to rain. 
  Use only as described in this manual. Use only manufacturer’s recommended attachments. 
  ALWAYS WEAR SAFETY GLASSES.  Everyday eyeglasses only have impact resistant lenses, they 

are not safety glasses. 

SAFETY PROCEDURES 

  Never allow unauthorized persons to operate lift. Thoroughly train new persons/employees in the use, 

operation and care of lift. 

CAUTION!

  

Power unit operates at high pressure.

  Remove passengers before raising vehicle. 
  Prohibit unauthorized persons from being in shop area while lift is in use. 
  Total lift capacity is 9,000 lbs (4,500 lbs. per axel).  Do not exceed this capacity. 
  Prior to lifting vehicle, walk around the lift and check for any objects that might interfere with the 

operation of lift and safety latches; tools, air hoses, shop equipment. 

  When approaching the lift with a vehicle, make sure to center the vehicle between the columns. Slowly 

drive the vehicle up with someone outside the vehicle guiding the driver. 

  Prior to lowering vehicle, walk around the lift and check for any objects that might interfere with the 

operation of lift and safety latches; tools, air hoses, shop equipment. 

  Slowly drive the vehicle on and off of the lift. Have someone outside the vehicle guide the driver. 

CAUTION! 

LUBRICATE ALL CABLE SHEAVES, BEARINGS, AND SHAFTS WITH GREASE PRIOR TO OPERATING 
THE LIFT.  LUBRICATE ALL ON AN ANNUAL BASIS. 

Motors and all electrical components are not sealed against the weather and moisture.  Install this lift in a 
protected indoor location. Failure by the owner to provide the recommended shelter could result in 
unsatisfactory lift performance, property damage, or personal injury. 

Содержание 4P9DXL

Страница 1: ...Jan 2017 Four Post Lift 9 000 lbs Capacity 4 500 lbs per axle INSTALLATION OWNERS MANUAL ATD 4P9DXL...

Страница 2: ...make note of any damage on the bill of lading 2 In case of freight damage call the truck line immediately and report the damage as a freight claim 3 IMPORTANT Make sure you have extra help or heavy d...

Страница 3: ...bmitted in writing to the factory for examination The user assumes full responsibility for any equipment damage personal injury or alteration of the equipment described in this manual or any subsequen...

Страница 4: ...ATD 4P9DXL_rev_0318 FLOOR PLAN LAYOUT ATD 4P9DXL...

Страница 5: ...floor is of questionable slope consider a survey of the site and or the possibility of pouring a new level concrete slab This lift is designed to be installed on a minimum of 4 thick 3000psi with ste...

Страница 6: ...ATD 4P9DXL OPTIONAL ACCESSORIES NOT SHOWN t RJ 45 Rolling Scissor Jack 4 500 lbs capacity Sub Runway Poly Caster Kit Crossbeam Jack Tool Tray Wheel Stop Column Power Unit Column Drip Trays Mainside Ru...

Страница 7: ...ware Box 2 While the Mainside Runway Fig 2 is upside down find the end of the Hydraulic Hose that is already connected to the Cylinder Locate hole on the side of the Mainside Runway 1 and install the...

Страница 8: ...our Columns from the shipping brackets and place the Power Unit Column 1 with mount bracket in the above chosen corner Arrange the other three Sub Columns 2 in the remaining corners 8 Unpack the Cross...

Страница 9: ...de each column After removing the top Nut from the Lock Ladder you are ready to install the Top Caps A B 10 65 on the columns 12 Be aware of the offset hole in column s Top Caps Arrange Top Caps so th...

Страница 10: ...ght until they are diagonally within 1 2 Note The variance will help in mounting the runways later 15 Lift and position each Runway into place and secure to top of Crossbeams with the provided Hex Bol...

Страница 11: ...ave assembly to reinstall the Cable due to welded cable guide brackets 17 Pull the slack for each Cable from the corner ends of the Mainside Runway and route the appropriate Cable s to each Column Top...

Страница 12: ...y routed through guide ring weldments located on the underside of the Mainside Runway Fig 8 19 Mount the Power Unit 8 to the Mainside Column with the attached mounting bracket using the Hardware provi...

Страница 13: ...ise lift off all locks until cables are supporting the lift Adjust the Cable s Nylon Lock Nut as shown in Fig 7 located on the top of each post until lift is level on crossbeams and runways This will...

Страница 14: ...m rails as shown on page 6 and on Fig 9 4 Install the four Pivot Pins 53 and Hairpin Cotter Pins 52 to secure Caster assembly to each Column 5 Lower the Lift confirming that the Caster assemblies enga...

Страница 15: ...ts and anchors typically 2 to 3 weeks ANCHORING TIPS 1 Use a concrete hammer drill with a carbide tip solid drill bit the same diameter as the anchor 3 4 775 to 787 inches diameter Do not use excessiv...

Страница 16: ...manual Use only manufacturer s recommended attachments ALWAYS WEAR SAFETY GLASSES Everyday eyeglasses only have impact resistant lenses they are not safety glasses SAFETY PROCEDURES Never allow unauth...

Страница 17: ...ther front nor rear heavy Raising Lift Push up switch to raise lift until runways clear the floor Stop and check for vehicle movement and vehicle weight distribution If secure raise to desired height...

Страница 18: ...e in operation Check safety latches for free movement and full engagement with rack Check hydraulic connections and hoses for leakage Check cables connections bends cracks and for loose fittings Check...

Страница 19: ...ickly while under a heavy load Lower the lift slowly under heavy loads Motor Hums and Will Not Run 1 Lift overloaded Remove excessive weight from lift WARNING The voltages used in the lift can cause d...

Страница 20: ...the check valve the flush plug to the left of the lowering valve Step 2 Using an Allen wrench and shop towel with shop towel in place to catch fluid loosen the check valve plug 2 turns to allow it to...

Страница 21: ...t will travel full height You should hear the locking latches click through all latch slots simultaneously 3 Lower lift onto top latch position 4 Check clearance starting with the right front column u...

Страница 22: ...ATD4P9DXL_rev_0318...

Страница 23: ...ATD4P9DXL_rev_0318...

Страница 24: ...ATD4P9DXL_rev_0318...

Страница 25: ...a l F 7 1 0 X D K 9 P F 7 1 6 1 m m 0 3 x 2 1 M w e r c S 8 1 0 X D K 9 P F 8 1 19 FP9KDX 019 KY 8440T 1000 8 Foot Step 1 20 FP9KDX 020 KY 8440T 3000 24 Drip Board Cover A 1 21 FP9KDX 021 KY 8440T 300...

Страница 26: ...8 FP9KDX 058 KY 8440T 3000 11 Cylinder Pin 1 2 m m 0 4 x 4 M n i P r e t t o C 9 5 0 X D K 9 P F 9 5 60 FP9KDX 060 KY 8440T 6000 2 Hose B 78 15 1 61 FP9KDX 061 P35BBD 6004 90 Hydra Fitting 1 62 FP9KDX...

Страница 27: ...8440T 2000 13 Latch Shaft 4 91 FP9KDX 091 KY 8440T 2000 9 Slack Cable Latch B 4 92 FP9KDX 092 KY 8440T 2000 12 1 Latch Shaft Spacer 4 93 FP9KDX 093 KY 8440T 2000 11 Spring Slack Cable 8 94 FP9KDX 094...

Страница 28: ...is not considered a warranty issue and therefore must be noted for any potential recovery with the shipping company The customer is required to notify Tuxedo of any missing parts within 72 hours Timel...

Отзывы: