Troubleshooting
97
Syn248 SB35020 Deskset User’s Guide
Back to Contents
Display Messages
The screen is blank or the Deskset menu does not work.
The screen displays
Joining Site...
for more than one minute.
The screen displays
Network Down
.
The screen displays
Synch Failed
.
Probable Cause
Corrective Action
There may be no power or
the Deskset may need to be
reset.
See
“To resolve a blank screen or device that
does not work at all:” on page 96
.
Reset the Deskset to factory defaults. Disconnect
the network cable from the Deskset and insert a
pen or paper clip into the reset hole and press for
more than five seconds.
Probable Cause
Corrective Action
The Gateway is failing to
synchronize with a Deskset
configured for a different
system configuration.
Always disconnect the network cable from the
Deskset before restoring factory defaults (by
pressing the
RESET
button more than five
seconds).
Probable Cause
Corrective Action
The network cable is
unplugged.
Ensure that one end of the network cable is
plugged into the port marked
on the
device and that the other end is plugged into
your office LAN.
Confirm that the light next to the
port is
green. If it is not, unplug the cable and plug it in
again.
There may be a problem with
the office network.
Check if other network devices, such as
computers, are communicating with the network.
If not, then contact your IT administrator.
Probable Cause
Corrective Action
The device synch failed when
trying to connect to the
system.
Reset the device. Insert a pen or paper clip into
the reset hole and press for less than five
seconds.
The maximum number of that
type of device has been
reached.
A device must be removed from the network and
deleted from the system before another device
can be added.