[5] Is waveform
between 1.8 volts
and 2.0 volts
peak-to-peak
[6] Remove scope
probe from pack and
switch to position
noted in Step 2
restore
ROS/OFF
066-03
166-03
166-68
LOCATION
LOCATION
FB214
066-33
066-39
166-33
166-39
066-68
Yes
No
[1] See CAUTION 1. Calibrate
[4] See NOTE 1. Connect scope
probe to terminal 018 of
clock chain removed from
note position of
ROS/OFF
FB214
pack associated with
switch
service [TABLE A]
[3] Rotate
ROS/OFF
switch
to
ROS
CLOCK
0
1
2
3
LOCATION
070-34
070-37
170-34
170-37
FB687
CHAIN
TABLE A
PWR SW
[2] At power switch [TABLE A],
VERIFY OSCILLATOR SIGNAL LEVEL — 39B OSCILLATOR
lighted
OS
and
OFF
NORM
lamps
CAUTION 1
Improper scope
calibration may
affect service
Connect scope probe
ground lead to
ground terminal
before making scope
probe signal
connection
NOTE 1
DLP
234-151-013
540
Issue 8
DEC 1995
PAGE 1 of 2